A computer‐aided diagnostic system for detecting diabetic retinopathy in optical coherence tomography images. Issue 3 (17th March 2017)
- Record Type:
- Journal Article
- Title:
- A computer‐aided diagnostic system for detecting diabetic retinopathy in optical coherence tomography images. Issue 3 (17th March 2017)
- Main Title:
- A computer‐aided diagnostic system for detecting diabetic retinopathy in optical coherence tomography images
- Authors:
- ElTanboly, Ahmed
Ismail, Marwa
Shalaby, Ahmed
Switala, Andy
El‐Baz, Ayman
Schaal, Shlomit
Gimel'farb, Georgy
El‐Azab, Magdi - Abstract:
- Abstract : Purpose: Detection (diagnosis) of diabetic retinopathy (DR) in optical coherence tomography (OCT) images for patients with type 2 diabetes, but almost clinically normal retina appearances. Methods: The proposed computer‐aided diagnostic (CAD) system detects the DR in three steps: (a) localizing and segmenting 12 distinct retinal layers on the OCT image; (b) deriving features of the segmented layers, and (c) learning most discriminative features and classifying each subject as normal or diabetic. To localise and segment the retinal layers, signals (intensities) of the OCT image are described with a joint Markov‐Gibbs random field (MGRF) model of intensities and shape descriptors. Each segmented layer is characterized with cumulative probability distribution functions (CDF) of its locally extracted features, such as reflectivity, curvature, and thickness. A multistage deep fusion classification network (DFCN) with a stack of non‐negativity‐constrained autoencoders (NCAE) is trained to select the most discriminative retinal layers' features and use their CDFs for detecting the DR. A training atlas was built using the OCT scans for 12 normal subjects and their maps of layers hand‐drawn by retina experts. Results: Preliminary experiments on 52 clinical OCT scans (26 normal and 26 with early‐stage DR, balanced between 40–79 yr old males and females; 40 training and 12 test subjects) gave the DR detection accuracy, sensitivity, and specificity of 92%; 83%, and 100%,Abstract : Purpose: Detection (diagnosis) of diabetic retinopathy (DR) in optical coherence tomography (OCT) images for patients with type 2 diabetes, but almost clinically normal retina appearances. Methods: The proposed computer‐aided diagnostic (CAD) system detects the DR in three steps: (a) localizing and segmenting 12 distinct retinal layers on the OCT image; (b) deriving features of the segmented layers, and (c) learning most discriminative features and classifying each subject as normal or diabetic. To localise and segment the retinal layers, signals (intensities) of the OCT image are described with a joint Markov‐Gibbs random field (MGRF) model of intensities and shape descriptors. Each segmented layer is characterized with cumulative probability distribution functions (CDF) of its locally extracted features, such as reflectivity, curvature, and thickness. A multistage deep fusion classification network (DFCN) with a stack of non‐negativity‐constrained autoencoders (NCAE) is trained to select the most discriminative retinal layers' features and use their CDFs for detecting the DR. A training atlas was built using the OCT scans for 12 normal subjects and their maps of layers hand‐drawn by retina experts. Results: Preliminary experiments on 52 clinical OCT scans (26 normal and 26 with early‐stage DR, balanced between 40–79 yr old males and females; 40 training and 12 test subjects) gave the DR detection accuracy, sensitivity, and specificity of 92%; 83%, and 100%, respectively. The 100% accuracy, sensitivity, and specificity have been obtained in the leave‐one‐out cross‐validation test for all the 52 subjects. Conclusion: Both the quantitative and visual assessments confirmed the high accuracy of the proposed computer‐assisted diagnostic system for early DR detection using the OCT retinal images. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 3(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 3(2017)
- Issue Display:
- Volume 44, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 3
- Issue Sort Value:
- 2017-0044-0003-0000
- Page Start:
- 914
- Page End:
- 923
- Publication Date:
- 2017-03-17
- Subjects:
- diabetic retinopathy (DR) -- joint image‐region‐map model -- Markov–Gibbs random field (MGRF) -- non‐negativity‐constrained autoencoder (NCAE) -- optical coherence tomography (OCT)
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12071 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9333.xml