Rapid emission angle selection for rotating‐shield brachytherapy. Issue 5 (30th April 2013)
- Record Type:
- Journal Article
- Title:
- Rapid emission angle selection for rotating‐shield brachytherapy. Issue 5 (30th April 2013)
- Main Title:
- Rapid emission angle selection for rotating‐shield brachytherapy
- Authors:
- Liu, Yunlong
Flynn, Ryan T.
Yang, Wenjun
Kim, Yusung
Bhatia, Sudershan K.
Sun, Wenqing
Wu, Xiaodong - Abstract:
- Abstract : Purpose: : The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: : Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent TM electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose‐volume optimization, with azimuthal shield emission angles of 90°, 180°, and 270°. The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose‐volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell‐time scaling was applied to all plans such that that high‐risk clinical target volume D 90 was maximized without violating the D 2cc tolerances of the rectum, bladder, and sigmoid colon. Results: : By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D 90 to 85–100 Gy10,Abstract : Purpose: : The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: : Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent TM electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose‐volume optimization, with azimuthal shield emission angles of 90°, 180°, and 270°. The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose‐volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell‐time scaling was applied to all plans such that that high‐risk clinical target volume D 90 was maximized without violating the D 2cc tolerances of the rectum, bladder, and sigmoid colon. Results: : By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D 90 to 85–100 Gy10, the delivery times used by REAS generated plans are 21.0% and 19.5% less than exhaustive surface optimized plans used by the two clinical cases. By setting the delivery time budget to 5–25 and 10–30 min/fx, respectively, for two the cases, the D 90 contributions for REAS are improved by 5.8% and 5.1% compared to the ERSO plans. The ranges used in this comparison were selected in order to keep both D 90 and the delivery time within acceptable limits. Conclusions: : The REAS method enables efficient RSBT treatment planning and delivery and provides treatment plans with comparable quality to those generated by exhaustive replanning with dose‐volume optimization. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 5(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 5(2013)
- Issue Display:
- Volume 40, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 5
- Issue Sort Value:
- 2013-0040-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-04-30
- Subjects:
- Dose‐volume analysis -- Numerical optimization -- Therapeutic applications, including brachytherapy
biological organs -- brachytherapy -- cancer -- dosimetry -- optimisation -- Pareto analysis -- tumours
brachytherapy -- intensity modulated brachytherapy -- IMBT -- rotating shield brachytherapy -- RSBT -- cervical cancer -- electronic brachytherapy
Radiation therapy
Dosimetry -- Cancer -- Brachytherapy -- Optimization -- Medical treatment planning -- Sequence analysis -- Radiation treatment -- Annealing -- Radiotherapy sources -- Tungsten
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4802750 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9334.xml