Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms. Issue 8 (18th July 2013)
- Record Type:
- Journal Article
- Title:
- Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms. Issue 8 (18th July 2013)
- Main Title:
- Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms
- Authors:
- Li, Xinhua
Zhang, Da
Liu, Bob - Abstract:
- Abstract : Purpose: : AAPM Task Group 111 proposed to measure the equilibrium dose‐pitch product D ̂ eq for scan modes involving table translation and the midpoint dose D L (0) for stationary‐table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners. Methods: : D ̂ eq was calculated from CTDI100 and ε(CTDI100 ) (CTDI100 efficiency), and D L (0) was calculated from D ̂ eq and the approach to equilibrium function H ( L ) = D L (0)/ D eq, where D eq was the equilibrium dose. CTDI100 may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDIVol using the central to peripheral CTDI100 ratio ( R 100 ). The authors have provided the required ε(CTDI100 ) and H ( L ) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, – (2012)10.1118/1.3678990 ; X. Li, D. Zhang, and B. Liu, Med. Phys., 031903 (10pp.) (2013)10.1118/1.4790470 ]. R 100 was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter. Results: : The calculated D L (0) and D L (0)/ D eq in PMMA and water cylinders were consistent with the measurements on two GE CT scannersAbstract : Purpose: : AAPM Task Group 111 proposed to measure the equilibrium dose‐pitch product D ̂ eq for scan modes involving table translation and the midpoint dose D L (0) for stationary‐table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners. Methods: : D ̂ eq was calculated from CTDI100 and ε(CTDI100 ) (CTDI100 efficiency), and D L (0) was calculated from D ̂ eq and the approach to equilibrium function H ( L ) = D L (0)/ D eq, where D eq was the equilibrium dose. CTDI100 may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDIVol using the central to peripheral CTDI100 ratio ( R 100 ). The authors have provided the required ε(CTDI100 ) and H ( L ) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, – (2012)10.1118/1.3678990 ; X. Li, D. Zhang, and B. Liu, Med. Phys., 031903 (10pp.) (2013)10.1118/1.4790470 ]. R 100 was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter. Results: : The calculated D L (0) and D L (0)/ D eq in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)10.1118/1.2757084 ], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)10.1120/jacmp.v13i6.3934 ], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)10.1118/1.3223634 ]. Conclusions: : D ̂ eq and D L (0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI100 ) and H ( L ) data in two previous papers. R 100 is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D eq ratio is about 1.50 and 1.12 times of R 100 for the 32‐ and 16‐cm diameter PMMA phantom, respectively. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 8(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 8(2013)
- Issue Display:
- Volume 40, Issue 8 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 8
- Issue Sort Value:
- 2013-0040-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-07-18
- Subjects:
- Dosimetry/exposure assessment -- Monte Carlo simulations -- Computed tomography
computerised tomography -- dosimetry -- Monte Carlo methods -- phantoms
computed tomography (CT) -- dose metric -- equilibrium dose‐pitch product -- midpoint dose -- calculation
Computerised tomographs
Dosimetry -- Computed tomography -- Germanium -- Image scanners -- Monte Carlo methods -- Biomedical modeling -- Exposure assessment -- Collimation -- Data analysis -- Medical imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4813899 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9347.xml