Evaluation of a synthetic single‐crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system. Issue 9 (5th August 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of a synthetic single‐crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system. Issue 9 (5th August 2015)
- Main Title:
- Evaluation of a synthetic single‐crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system
- Authors:
- Mancosu, Pietro
Reggiori, Giacomo
Stravato, Antonella
Gaudino, Anna
Lobefalo, Francesca
Palumbo, Valentina
Navarria, Piera
Ascolese, Anna
Picozzi, Piero
Marinelli, Marco
Verona‐Rinati, Gianluca
Tomatis, Stefano
Scorsetti, Marta - Abstract:
- Abstract : Purpose: To evaluate the new commercial PTW‐60019 synthetic single‐crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW‐60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW‐60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW‐60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW‐60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW‐60019 is a suitable detector for commissioning and routine use of Gamma KnifeAbstract : Purpose: To evaluate the new commercial PTW‐60019 synthetic single‐crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW‐60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW‐60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW‐60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW‐60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW‐60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 9(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 9(2015)
- Issue Display:
- Volume 42, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 9
- Issue Sort Value:
- 2015-0042-0009-0000
- Page Start:
- 5035
- Page End:
- 5041
- Publication Date:
- 2015-08-05
- Subjects:
- diamond -- diodes -- dosimeters -- dosimetry -- radiation therapy
Dosimetry/exposure assessment -- Therapeutic applications, including brachytherapy
Radiation therapy -- Dosimeters -- Scintigraphy
single microDiamond detector -- small field dosimetry -- Gamma Knife Perfexion -- output factor
Collimators -- Dosimetry -- Diamond -- Monte Carlo methods -- Particle beam detectors -- Error analysis -- Radiosurgery -- Single crystals -- Photons -- Elemental semiconductors
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4927569 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9342.xml