Airway support using a pediatric intubation tube in adult patients with atrial fibrillation: A simple and unique method to prevent heart movement during catheter ablation under continuous deep sedation. Issue 4 (21st February 2017)
- Record Type:
- Journal Article
- Title:
- Airway support using a pediatric intubation tube in adult patients with atrial fibrillation: A simple and unique method to prevent heart movement during catheter ablation under continuous deep sedation. Issue 4 (21st February 2017)
- Main Title:
- Airway support using a pediatric intubation tube in adult patients with atrial fibrillation: A simple and unique method to prevent heart movement during catheter ablation under continuous deep sedation
- Authors:
- Takigawa, Masateru
Takahashi, Atsushi
Kuwahara, Taishi
Okubo, Kenji
Nakashima, Emiko
Watari, Yuji
Yamao, Kazuya
Nakajima, Jun
Tanaka, Yasuaki
Takagi, Katsumasa
Kimura, Shigeki
Hikita, Hiroyuki
Hirao, Kenzo
Isobe, Mitsuaki - Abstract:
- Abstract: Background: The present study aimed to elucidate the safety and effectiveness of a noble and unique airway management technique in which a pediatric intubation tube is used in adult patients with atrial fibrillation (AF) undergoing catheter ablation (CA) under continuous deep sedation. Methods: In total, 246 consecutive patients with AF (mean age, 65±10 years; 60 women) underwent CA under dexmedetomidine‐based continuous deep sedation. A 4‐mm pediatric intubation tube guided by a 10‐French intratracheal suction tube was inserted smoothly, and the tip of the tube was located at the base of the epiglottis. The maximum shifting distance of the heart (MSDH) was measured with the 3D mapping system (Ensite NavX system) before and after inserting the pediatric intubation tube. Results: At baseline, the MSDH of patients under continuous deep sedation was 23±14 mm. The pediatric intubation tube reduced the MSDH to 13±6 mm (mean reduction from baseline, 38.4±21.7%; P <0.0001). In contrast, oxygen saturation was significantly increased from 89±8% to 95±3% ( P <0.0001). The mean distance between the nostril and base of the epiglottis was 16.6±0.5 mm. Major periprocedural complications occurred in 9 (3.6%) patients including 3 (1.2%) cardiac tamponade and 6 (2.4%) phrenic nerve injury cases. Larger MSDH (odds ratio, 1.13; 95% confidence interval, 1.04–1.25; P =0.007) was a significant predictor of major periprocedural complications. No major airway complications occurred,Abstract: Background: The present study aimed to elucidate the safety and effectiveness of a noble and unique airway management technique in which a pediatric intubation tube is used in adult patients with atrial fibrillation (AF) undergoing catheter ablation (CA) under continuous deep sedation. Methods: In total, 246 consecutive patients with AF (mean age, 65±10 years; 60 women) underwent CA under dexmedetomidine‐based continuous deep sedation. A 4‐mm pediatric intubation tube guided by a 10‐French intratracheal suction tube was inserted smoothly, and the tip of the tube was located at the base of the epiglottis. The maximum shifting distance of the heart (MSDH) was measured with the 3D mapping system (Ensite NavX system) before and after inserting the pediatric intubation tube. Results: At baseline, the MSDH of patients under continuous deep sedation was 23±14 mm. The pediatric intubation tube reduced the MSDH to 13±6 mm (mean reduction from baseline, 38.4±21.7%; P <0.0001). In contrast, oxygen saturation was significantly increased from 89±8% to 95±3% ( P <0.0001). The mean distance between the nostril and base of the epiglottis was 16.6±0.5 mm. Major periprocedural complications occurred in 9 (3.6%) patients including 3 (1.2%) cardiac tamponade and 6 (2.4%) phrenic nerve injury cases. Larger MSDH (odds ratio, 1.13; 95% confidence interval, 1.04–1.25; P =0.007) was a significant predictor of major periprocedural complications. No major airway complications occurred, except in 3 patients (1.2%) who had minor nasal bleeding. Conclusion: This unique airway management technique using a pediatric intubation tube for CA procedures performed in adult patients with AF under continuous deep sedation was easy, safe, and effective. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 33:Issue 4(2017)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 33:Issue 4(2017)
- Issue Display:
- Volume 33, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 4
- Issue Sort Value:
- 2017-0033-0004-0000
- Page Start:
- 262
- Page End:
- 268
- Publication Date:
- 2017-02-21
- Subjects:
- Atrial fibrillation -- Catheter ablation -- Complication -- Intubation -- Sedation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2017.01.003 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9338.xml