Audiovisual biofeedback improves motion prediction accuracy. Issue 4 (13th March 2013)
- Record Type:
- Journal Article
- Title:
- Audiovisual biofeedback improves motion prediction accuracy. Issue 4 (13th March 2013)
- Main Title:
- Audiovisual biofeedback improves motion prediction accuracy
- Authors:
- Pollock, Sean
Lee, Danny
Keall, Paul
Kim, Taeho - Abstract:
- Abstract : Purpose: : The accuracy of motion prediction, utilized to overcome the system latency of motion management radiotherapy systems, is hampered by irregularities present in the patients' respiratory pattern. Audiovisual (AV) biofeedback has been shown to reduce respiratory irregularities. The aim of this study was to test the hypothesis that AV biofeedback improves the accuracy of motion prediction. Methods: : An AV biofeedback system combined with real‐time respiratory data acquisition and MR images were implemented in this project. One‐dimensional respiratory data from (1) the abdominal wall (30 Hz) and (2) the thoracic diaphragm (5 Hz) were obtained from 15 healthy human subjects across 30 studies. The subjects were required to breathe with and without the guidance of AV biofeedback during each study. The obtained respiratory signals were then implemented in a kernel density estimation prediction algorithm. For each of the 30 studies, five different prediction times ranging from 50 to 1400 ms were tested (150 predictions performed). Prediction error was quantified as the root mean square error (RMSE); the RMSE was calculated from the difference between the real and predicted respiratory data. The statistical significance of the prediction results was determined by the Student's t ‐test. Results: : Prediction accuracy was considerably improved by the implementation of AV biofeedback. Of the 150 respiratory predictions performed, prediction accuracy was improved 69%Abstract : Purpose: : The accuracy of motion prediction, utilized to overcome the system latency of motion management radiotherapy systems, is hampered by irregularities present in the patients' respiratory pattern. Audiovisual (AV) biofeedback has been shown to reduce respiratory irregularities. The aim of this study was to test the hypothesis that AV biofeedback improves the accuracy of motion prediction. Methods: : An AV biofeedback system combined with real‐time respiratory data acquisition and MR images were implemented in this project. One‐dimensional respiratory data from (1) the abdominal wall (30 Hz) and (2) the thoracic diaphragm (5 Hz) were obtained from 15 healthy human subjects across 30 studies. The subjects were required to breathe with and without the guidance of AV biofeedback during each study. The obtained respiratory signals were then implemented in a kernel density estimation prediction algorithm. For each of the 30 studies, five different prediction times ranging from 50 to 1400 ms were tested (150 predictions performed). Prediction error was quantified as the root mean square error (RMSE); the RMSE was calculated from the difference between the real and predicted respiratory data. The statistical significance of the prediction results was determined by the Student's t ‐test. Results: : Prediction accuracy was considerably improved by the implementation of AV biofeedback. Of the 150 respiratory predictions performed, prediction accuracy was improved 69% (103/150) of the time for abdominal wall data, and 78% (117/150) of the time for diaphragm data. The average reduction in RMSE due to AV biofeedback over unguided respiration was 26% ( p < 0.001) and 29% ( p < 0.001) for abdominal wall and diaphragm respiratory motion, respectively. Conclusions: : This study was the first to demonstrate that the reduction of respiratory irregularities due to the implementation of AV biofeedback improves prediction accuracy. This would result in increased efficiency of motion management techniques affected by system latencies used in radiotherapy. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 4(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 4(2013)
- Issue Display:
- Volume 40, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2013-0040-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-03-13
- Subjects:
- Magnetic resonance imaging -- Pneumodyamics, respiration -- Approximations and expansions -- Numerical approximation and analysis
biomedical MRI -- data acquisition -- feedback -- lung -- mean square error methods -- motion estimation -- pneumodynamics -- radiation therapy
motion prediction -- audiovisual biofeedback -- motion management -- system latency
Involving electronic [emr] or nuclear [nmr] magnetic resonance, e.g. magnetic resonance imaging -- Radiation therapy -- Analysis of motion
Biofeedback -- Pneumodynamics -- Cancer -- Radiation therapy -- Medical imaging -- Dosimetry -- Medical magnetic resonance imaging -- Interpolation -- Tissues -- Ultrasonography
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4794497 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9341.xml