CT perfusion analysis by nonlinear regression for predicting hemorrhagic transformation in ischemic stroke. Issue 8 (13th July 2015)
- Record Type:
- Journal Article
- Title:
- CT perfusion analysis by nonlinear regression for predicting hemorrhagic transformation in ischemic stroke. Issue 8 (13th July 2015)
- Main Title:
- CT perfusion analysis by nonlinear regression for predicting hemorrhagic transformation in ischemic stroke
- Authors:
- Bennink, Edwin
Horsch, Alexander D.
Dankbaar, Jan Willem
Velthuis, Birgitta K.
Viergever, Max A.
de Jong, Hugo W. A. M. - Abstract:
- Abstract : Purpose: Intravenous thrombolysis can improve clinical outcome in acute ischemic stroke patients but increases the risk of hemorrhagic transformation (HT). Blood–brain barrier damage, which can be quantified by the vascular permeability for contrast agents, is a potential predictor for HT. This study aimed to assess whether this prediction can be improved by measuring vascular permeability using a novel fast nonlinear regression (NLR) method instead of Patlak analysis. Methods: From a prospective ischemic stroke multicenter cohort study, 20 patients with HT on follow‐up imaging and 40 patients without HT were selected. The permeability transfer constant K trans was measured in three ways; using standard Patlak analysis, Patlak analysis with a fixed offset, and the NLR method. In addition, the permeability‐surface (PS) area product and the conventional perfusion parameters (blood volume, flow, and mean transit time) were measured using the NLR method. Relative values were calculated in two ways, i.e., by dividing the average in the infarct core by the average in the contralateral hemisphere, and by dividing the average in the ipsilateral hemisphere by the average in the contralateral hemisphere. Mann–Whitney U tests and receiver operating characteristic (ROC) analyses were performed to assess the discriminative power of each of the relative parameters. Results: Both the infarct‐core and whole‐hemisphere averaged relative K trans (r K trans ) values, measured withAbstract : Purpose: Intravenous thrombolysis can improve clinical outcome in acute ischemic stroke patients but increases the risk of hemorrhagic transformation (HT). Blood–brain barrier damage, which can be quantified by the vascular permeability for contrast agents, is a potential predictor for HT. This study aimed to assess whether this prediction can be improved by measuring vascular permeability using a novel fast nonlinear regression (NLR) method instead of Patlak analysis. Methods: From a prospective ischemic stroke multicenter cohort study, 20 patients with HT on follow‐up imaging and 40 patients without HT were selected. The permeability transfer constant K trans was measured in three ways; using standard Patlak analysis, Patlak analysis with a fixed offset, and the NLR method. In addition, the permeability‐surface (PS) area product and the conventional perfusion parameters (blood volume, flow, and mean transit time) were measured using the NLR method. Relative values were calculated in two ways, i.e., by dividing the average in the infarct core by the average in the contralateral hemisphere, and by dividing the average in the ipsilateral hemisphere by the average in the contralateral hemisphere. Mann–Whitney U tests and receiver operating characteristic (ROC) analyses were performed to assess the discriminative power of each of the relative parameters. Results: Both the infarct‐core and whole‐hemisphere averaged relative K trans (r K trans ) values, measured with the NLR method, were significantly higher in the patients who developed HT as compared with those who did not. The r K trans measured with standard Patlak analysis was not significantly different. The relative PS (rPS), measured with NLR, had the highest discriminative power ( P = 0.002). ROC analysis of rPS showed an area under the curve (AUC) of 0.75 (95% confidence interval: 0.62–0.89) and a sensitivity of 0.75 at a specificity of 0.75. The AUCs of the Patlak r K trans, the Patlak r K trans with fixed offset, and the NLR r K trans were 0.58, 0.66, and 0.67, respectively. Conclusions: CT perfusion analysis may aid in predicting HT, but standard Patlak analysis did not provide estimates for r K trans that were significantly higher in the HT group. The rPS, measured in the infarct core with NLR, had superior discriminative power compared with K trans measured with either Patlak analysis with a fixed offset or NLR, and conventional perfusion parameters. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 8(2015)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 8(2015)Part 1
- Issue Display:
- Volume 42, Issue 8, Part 1 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2015-0042-0008-0001
- Page Start:
- 4610
- Page End:
- 4618
- Publication Date:
- 2015-07-13
- Subjects:
- blood -- brain -- computerised tomography -- diagnostic radiography -- diseases -- haemorheology -- medical image processing -- neurophysiology -- permeability -- regression analysis
Computed tomography -- X‐ray imaging -- Blood‐brain barrier -- Fluid mechanics and rheology
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications
CT perfusion -- stroke -- hemorrhagic transformation -- nonlinear regression -- Patlak analysis
Stroke -- Computed tomography -- Haemodynamics -- Blood flow measurement -- Tissues -- Brain -- Image analysis -- Medical image noise -- Dosimetry
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4923751 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9324.xml