Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model. Issue 7 (11th June 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model. Issue 7 (11th June 2015)
- Main Title:
- Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model
- Authors:
- O'Connell, Dylan P.
Thomas, David H.
Dou, Tai H.
Lamb, James M.
Feingold, Franklin
Low, Daniel A.
Fuld, Matthew K.
Sieren, Jered P.
Sloan, Chelsea M.
Shirk, Melissa A.
Hoffman, Eric A.
Hofmann, Christian - Abstract:
- Abstract : Purpose: To demonstrate that a "5DCT" technique which utilizes fast helical acquisition yields the same respiratory‐gated images as a commercial technique for regular, mechanically produced breathing cycles. Methods: Respiratory‐gated images of an anesthetized, mechanically ventilated pig were generated using a Siemens low‐pitch helical protocol and 5DCT for a range of breathing rates and amplitudes and with standard and low dose imaging protocols. 5DCT reconstructions were independently evaluated by measuring the distances between tissue positions predicted by a 5D motion model and those measured using deformable registration, as well by reconstructing the originally acquired scans. Discrepancies between the 5DCT and commercial reconstructions were measured using landmark correspondences. Results: The mean distance between model predicted tissue positions and deformably registered tissue positions over the nine datasets was 0.65 ± 0.28 mm. Reconstructions of the original scans were on average accurate to 0.78 ± 0.57 mm. Mean landmark displacement between the commercial and 5DCT images was 1.76 ± 1.25 mm while the maximum lung tissue motion over the breathing cycle had a mean value of 27.2 ± 4.6 mm. An image composed of the average of 30 deformably registered images acquired with a low dose protocol had 6 HU image noise (single standard deviation) in the heart versus 31 HU for the commercial images. Conclusions: An end to end evaluation of the 5DCT technique wasAbstract : Purpose: To demonstrate that a "5DCT" technique which utilizes fast helical acquisition yields the same respiratory‐gated images as a commercial technique for regular, mechanically produced breathing cycles. Methods: Respiratory‐gated images of an anesthetized, mechanically ventilated pig were generated using a Siemens low‐pitch helical protocol and 5DCT for a range of breathing rates and amplitudes and with standard and low dose imaging protocols. 5DCT reconstructions were independently evaluated by measuring the distances between tissue positions predicted by a 5D motion model and those measured using deformable registration, as well by reconstructing the originally acquired scans. Discrepancies between the 5DCT and commercial reconstructions were measured using landmark correspondences. Results: The mean distance between model predicted tissue positions and deformably registered tissue positions over the nine datasets was 0.65 ± 0.28 mm. Reconstructions of the original scans were on average accurate to 0.78 ± 0.57 mm. Mean landmark displacement between the commercial and 5DCT images was 1.76 ± 1.25 mm while the maximum lung tissue motion over the breathing cycle had a mean value of 27.2 ± 4.6 mm. An image composed of the average of 30 deformably registered images acquired with a low dose protocol had 6 HU image noise (single standard deviation) in the heart versus 31 HU for the commercial images. Conclusions: An end to end evaluation of the 5DCT technique was conducted through landmark based comparison to breathing gated images acquired with a commercial protocol under highly regular ventilation. The techniques were found to agree to within 2 mm for most respiratory phases and most points in the lung. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 7(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 7(2015)
- Issue Display:
- Volume 42, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2015-0042-0007-0000
- Page Start:
- 4033
- Page End:
- 4042
- Publication Date:
- 2015-06-11
- Subjects:
- biological tissues -- cardiology -- computerised tomography -- image motion analysis -- image reconstruction -- image registration -- lung -- medical image processing -- pneumodynamics
Computed tomography -- Reconstruction -- Registration -- Noise -- Pneumodyamics, respiration
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Analysis of motion
4DCT -- breathing motion modeling
Medical image reconstruction -- Image reconstruction -- Lungs -- Tissues -- Medical image artifacts -- Computed tomography -- Image registration -- Dosimetry -- Cancer
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4922201 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9325.xml