Remote magnetic catheter navigation versus conventional ablation in atrial fibrillation ablation: Fluoroscopy reduction. Issue 3 (10th November 2016)
- Record Type:
- Journal Article
- Title:
- Remote magnetic catheter navigation versus conventional ablation in atrial fibrillation ablation: Fluoroscopy reduction. Issue 3 (10th November 2016)
- Main Title:
- Remote magnetic catheter navigation versus conventional ablation in atrial fibrillation ablation: Fluoroscopy reduction
- Authors:
- Lim, Paul Chun Yih
Toh, Joseph Jia Hong
Loh, Julian Kenrick Xing Yuan
Lee, Edward Chun Yi
Chong, Daniel Thuan Tee
Tan, Boon Yew
Ho, Kah Leng
Ching, Chi Keong
Teo, Wee Siong - Abstract:
- Abstract: Background: Percutaneous transcatheter radiofrequency ablation of atrial fibrillation with remote controlled magnetic navigation (RMN) has been shown to reduce radiation exposure to patients and physicians compared with conventional manual (MAN) ablation techniques. Methods: Catheter ablation for atrial fibrillation was performed utilizing RMN in 214 consecutive patients and MAN ablation techniques in 229 patients. We compared the fluoroscopy and procedural times between RMN and MAN catheter ablation of atrial fibrillation. Secondary objectives included comparing acute procedural success and short‐term complication rates between both ablation strategies. Results: Fluoroscopy time was significantly shorter in the RMN group than the MAN group (53.5±30.1 vs 68.1±27.6 min, respectively; p <0.01); however, the total procedural time was longer in the RMN group (280.2±74.4 min vs 213.1±64.75, respectively; p >0.001). Further subgroup analysis of the most recent 50 ablations each from the RMN and MAN groups, to attenuate the RMN learning curve effect, showed an even greater difference in fluoroscopy time (RMN vs MAN: 53.5±30.1 vs 68.1±27.6 min), though a consistently longer procedure time with RMN (249.5±65.5 vs 186.3±65.6 min, respectively). The acute procedural success rate was comparable between the groups (98.6% vs 95.6%, respectively; p =0.07). The rates of acute complications were similar in both groups (2.3% vs 4.8%, respectively; p =0.16). Conclusions: InAbstract: Background: Percutaneous transcatheter radiofrequency ablation of atrial fibrillation with remote controlled magnetic navigation (RMN) has been shown to reduce radiation exposure to patients and physicians compared with conventional manual (MAN) ablation techniques. Methods: Catheter ablation for atrial fibrillation was performed utilizing RMN in 214 consecutive patients and MAN ablation techniques in 229 patients. We compared the fluoroscopy and procedural times between RMN and MAN catheter ablation of atrial fibrillation. Secondary objectives included comparing acute procedural success and short‐term complication rates between both ablation strategies. Results: Fluoroscopy time was significantly shorter in the RMN group than the MAN group (53.5±30.1 vs 68.1±27.6 min, respectively; p <0.01); however, the total procedural time was longer in the RMN group (280.2±74.4 min vs 213.1±64.75, respectively; p >0.001). Further subgroup analysis of the most recent 50 ablations each from the RMN and MAN groups, to attenuate the RMN learning curve effect, showed an even greater difference in fluoroscopy time (RMN vs MAN: 53.5±30.1 vs 68.1±27.6 min), though a consistently longer procedure time with RMN (249.5±65.5 vs 186.3±65.6 min, respectively). The acute procedural success rate was comparable between the groups (98.6% vs 95.6%, respectively; p =0.07). The rates of acute complications were similar in both groups (2.3% vs 4.8%, respectively; p =0.16). Conclusions: In radiofrequency ablation of atrial fibrillation, RMN appears to significantly reduce fluoroscopy time compared with conventional MAN ablation, though at a cost of increased total procedural time, with comparable acute success rates and safety profile. A reduction in procedure and fluoroscopy times is possible with gaining experience. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 33:Issue 3(2017)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 33:Issue 3(2017)
- Issue Display:
- Volume 33, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2017-0033-0003-0000
- Page Start:
- 167
- Page End:
- 171
- Publication Date:
- 2016-11-10
- Subjects:
- Atrial fibrillation -- Remote magnetic navigation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2016.08.007 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9325.xml