Investigating the use of nonattenuation corrected PET images for the attenuation correction of PET data. Issue 8 (26th July 2013)
- Record Type:
- Journal Article
- Title:
- Investigating the use of nonattenuation corrected PET images for the attenuation correction of PET data. Issue 8 (26th July 2013)
- Main Title:
- Investigating the use of nonattenuation corrected PET images for the attenuation correction of PET data
- Authors:
- Chang, Tingting
Diab, Rami H.
Clark, John W.
Mawlawi, Osama R. - Abstract:
- Abstract : Purpose: : The aim of this study is to investigate the feasibility of using the nonattenuated PET images (PET‐NAC) as a means for the AC of PET data. Methods: : A three‐step iterative segmentation process is proposed. In step 1, a patient's body contour is segmented from the PET‐NAC using an active contour algorithm. Voxels inside the contour are then assigned a value of 0.096 cm −1 to represent the attenuation coefficient of soft tissue at 511 keV. This segmented attenuation map is then used to correct for attenuation the raw PET data and the resulting PET images are used as the input to Step 2 of the process. In step 2, the lung region is segmented using an optimal thresholding approach and the corresponding voxels are assigned a value of 0.024 cm −1 representing the attenuation coefficients of lung tissue at 511 keV. The updated attenuation map is then used for a second time to correct for attenuation the raw PET data, and the resulting PET images are used as the input to step 3. The purpose of Step 3 is to delineate parts of the heart and liver in the lung contour using a region growing approach since these parts were unavoidably excluded in the lung contour in step 2. These parts are then corrected by using a value of 0.096 cm −1 in the attenuation map. Finally the attenuation coefficients of the bed are included based on CT images to eliminate the impact of the couch on the accuracy of AC. The final attenuation map is then used to AC the raw PET data andAbstract : Purpose: : The aim of this study is to investigate the feasibility of using the nonattenuated PET images (PET‐NAC) as a means for the AC of PET data. Methods: : A three‐step iterative segmentation process is proposed. In step 1, a patient's body contour is segmented from the PET‐NAC using an active contour algorithm. Voxels inside the contour are then assigned a value of 0.096 cm −1 to represent the attenuation coefficient of soft tissue at 511 keV. This segmented attenuation map is then used to correct for attenuation the raw PET data and the resulting PET images are used as the input to Step 2 of the process. In step 2, the lung region is segmented using an optimal thresholding approach and the corresponding voxels are assigned a value of 0.024 cm −1 representing the attenuation coefficients of lung tissue at 511 keV. The updated attenuation map is then used for a second time to correct for attenuation the raw PET data, and the resulting PET images are used as the input to step 3. The purpose of Step 3 is to delineate parts of the heart and liver in the lung contour using a region growing approach since these parts were unavoidably excluded in the lung contour in step 2. These parts are then corrected by using a value of 0.096 cm −1 in the attenuation map. Finally the attenuation coefficients of the bed are included based on CT images to eliminate the impact of the couch on the accuracy of AC. The final attenuation map is then used to AC the raw PET data and generates the final PET image, which we name iterative AC PET (PET‐IAC). To assess the proposed segmentation approach, a phantom and 14 patients (with a total of 55 lesions including bone) were scanned on a GE Discovery‐RX PET/CT scanner. PET‐IAC images were generated using the proposed process and compared to those of CT‐AC PET (PET‐CTAC). Visual inspection, lesion SUV, and voxel by voxel histograms between PET‐IAC and PET‐CTAC for phantom and patient studies were performed to assess the accuracy of image quantification. Results: : Visual inspection showed a small difference in lung parenchyma between the PET‐IAC and PET‐CTAC. Tumor SUV based on PET‐IAC were on average different by 3% ± 9% (6% ± 7%) compared to the SUVs from the PET‐CTAC in the phantom (patient) studies. For bone lesions only, the average difference was 3% ± 6%. The histogram comparing PET‐CTAC and PET‐IAC resulted in an average regression line of y = (1.08 ± 0.07) x + (0.00007 ± 0.0013), with R 2 = 0.978 ± 0.0057. Conclusions: : Preliminary results suggest that PET‐NAC for the AC of PET images is feasible. Such an approach can potentially be used for dedicated PET or PET/MR hybrid systems while minimizing scan time or potential image artifacts, respectively. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 8(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 8(2013)
- Issue Display:
- Volume 40, Issue 8 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 8
- Issue Sort Value:
- 2013-0040-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-07-26
- Subjects:
- Positron emission tomography (PET) -- Artifacts and distortion -- Segmentation -- Computed tomography
bone -- cardiology -- image segmentation -- inspection -- liver -- lung -- medical image processing -- phantoms -- positron emission tomography -- tumours
PET -- attenuation correction -- segmentation
Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general
Medical imaging -- Positron emission tomography -- Lungs -- Computed tomography -- Tissues -- Medical image segmentation -- Cancer -- Medical magnetic resonance imaging -- Optical inspection -- Medical image artifacts
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4816304 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9328.xml