Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source. Issue 2 (23rd January 2014)
- Record Type:
- Journal Article
- Title:
- Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source. Issue 2 (23rd January 2014)
- Main Title:
- Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source
- Authors:
- Fulkerson, Regina K.
Micka, John A.
DeWerd, Larry A. - Abstract:
- Abstract : Purpose: : Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x‐ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR) 192 Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR 192 Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross‐over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low‐energy superficial x‐ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: : This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) andAbstract : Purpose: : Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x‐ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR) 192 Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR 192 Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross‐over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low‐energy superficial x‐ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: : This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and 192 Ir sources (Part II). Air‐kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free‐Air Chamber, as well as several models of small‐volume ionization chambers to obtain an air‐kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator‐specific absorbed dose to water at the treatment surface from the measured air‐kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in‐phantom. Results: : Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator‐specific dose to water at the treatment surface based on a measured air‐kerma rate. Conclusions: : The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 2(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 2(2014)
- Issue Display:
- Volume 41, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2014-0041-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-01-23
- Subjects:
- Dose‐volume analysis -- Dosimetry/exposure assessment -- Therapeutic applications, including brachytherapy -- Monte Carlo methods -- Dosimetry
brachytherapy -- cancer -- dosimetry -- electron beam applications -- ionisation chambers -- iridium -- Monte Carlo methods -- phantoms -- quality assurance -- radioactive sources -- skin -- statistical distributions
skin cancer -- surface applicator -- HDR
Radiation therapy -- Measurement of nuclear or x‐radiation -- Radioactive sources -- Tubes for determining the presence, intensity, density or energy of radiation or particles -- Scintigraphy -- Radioactive sources other than neutron sources (radioactive dressings A61M36/14)
Dosimetry -- Calibration -- Thermoluminescent dosimeters -- Surface treatments -- Surface ionization -- Ionization chambers -- Monte Carlo methods -- Photons -- Error analysis -- Field aligned currents
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4862505 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9325.xml