Immediate discontinuation of ablation during pulmonary vein isolation remarkably decreases the incidence of esophageal thermal lesions even when using steerable sheaths. Issue 1 (3rd June 2016)
- Record Type:
- Journal Article
- Title:
- Immediate discontinuation of ablation during pulmonary vein isolation remarkably decreases the incidence of esophageal thermal lesions even when using steerable sheaths. Issue 1 (3rd June 2016)
- Main Title:
- Immediate discontinuation of ablation during pulmonary vein isolation remarkably decreases the incidence of esophageal thermal lesions even when using steerable sheaths
- Authors:
- Watanabe, Norikazu
Chiba, Yuta
Onishi, Yoshimi
Kawasaki, Shiro
Munetsugu, Yumi
Onuma, Yoshimasa
Itou, Hiroyuki
Onuki, Tatsuya
Minoura, Yoshino
Adachi, Taro
Kawamura, Mitsuharu
Asano, Taku
Tanno, Kaoru
Kubota, Yutarou
Konishi, Kazuo
Kobayashi, Youichi - Abstract:
- Abstract: Background: Left atrial–esophageal fistulas (LAEFs) are serious complications with high mortality after atrial fibrillation radiofrequency ablation (AFRA). Decreasing the incidence of esophageal thermal lesions (EsoTLs) that may lead to LAEFs is important. The aim of this study was to suppress EsoTL development and determine the appropriate alarm setting for a temperature‐monitoring probe by using steerable sheath (STS) methods. Methods: We enrolled 82 consecutive patients (mean, 61.9±11.7 years; 75.6% men) who underwent AFRA, including pulmonary vein isolation for symptomatic, drug‐refractory atrial fibrillation with esophageal temperature monitoring by using STS between January 2011 and April 2014. All patients underwent upper gastrointestinal endoscopy (UGE) 1–3 days after AFRA. The timing of ablation discontinuation in the first 17 patients was determined by each physician during AFRA (only monitoring group, OM). In the next 65 patients, physicians were to immediately discontinue ablation when an alarm set at 39 °C went off (instruction group, INS). We compared two groups with respect to the incidence of EsoTLs. Results: Among the 82 patients, 5 (6.1%) had EsoTLs after AFRA. EsoTLs occurred in 3 of 17 patients (17.6%) and 2 of 65 patients (3.1%) in the OM and INS groups, respectively. The incidence of EsoTLs in the INS group was significantly lower than that in the OM group ( p =0.0254). EsoTL did not occur at maximal temperature less than 39 °C, measured byAbstract: Background: Left atrial–esophageal fistulas (LAEFs) are serious complications with high mortality after atrial fibrillation radiofrequency ablation (AFRA). Decreasing the incidence of esophageal thermal lesions (EsoTLs) that may lead to LAEFs is important. The aim of this study was to suppress EsoTL development and determine the appropriate alarm setting for a temperature‐monitoring probe by using steerable sheath (STS) methods. Methods: We enrolled 82 consecutive patients (mean, 61.9±11.7 years; 75.6% men) who underwent AFRA, including pulmonary vein isolation for symptomatic, drug‐refractory atrial fibrillation with esophageal temperature monitoring by using STS between January 2011 and April 2014. All patients underwent upper gastrointestinal endoscopy (UGE) 1–3 days after AFRA. The timing of ablation discontinuation in the first 17 patients was determined by each physician during AFRA (only monitoring group, OM). In the next 65 patients, physicians were to immediately discontinue ablation when an alarm set at 39 °C went off (instruction group, INS). We compared two groups with respect to the incidence of EsoTLs. Results: Among the 82 patients, 5 (6.1%) had EsoTLs after AFRA. EsoTLs occurred in 3 of 17 patients (17.6%) and 2 of 65 patients (3.1%) in the OM and INS groups, respectively. The incidence of EsoTLs in the INS group was significantly lower than that in the OM group ( p =0.0254). EsoTL did not occur at maximal temperature less than 39 °C, measured by using esophageal temperature‐monitoring probe. Conclusions: Immediate discontinuation of ablation during pulmonary vein isolation remarkably decreased the incidence of EsoTLs, even when using STS. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 33:Issue 1(2017)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 33:Issue 1(2017)
- Issue Display:
- Volume 33, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2017-0033-0001-0000
- Page Start:
- 23
- Page End:
- 27
- Publication Date:
- 2016-06-03
- Subjects:
- Atrial fibrillation ablation -- Esophageal monitoring -- Esophageal thermal lesion -- Steerable sheath
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2016.05.001 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9329.xml