- A 4D digital phantom for patient‐specific simulation of brain CT perfusion protocols. Issue 7 (12th June 2014)
- Main Title:
- A 4D digital phantom for patient‐specific simulation of brain CT perfusion protocols
- Authors:
- van den Boom, Rieneke
Manniesing, Rashindra
Oei, Marcel T. H.
van der Woude, Willem‐Jan
Smit, Ewoud J.
Laue, Hendrik O. A.
van Ginneken, Bram
Prokop, Mathias - Abstract:
- Abstract : Purpose: Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data, and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters. The authors expand this idea by using realistic noise patterns and measured tissue attenuation curves representing patient‐specific hemodynamics. The purpose of this work is to validate that this approach can realistically simulate mean perfusion values and noise on perfusion data for individual patients. Methods: The proposed 4D digital phantom consists of three major components: (1) a definition of the spatial structure of various brain tissues within the phantom, (2) measured tissue attenuation curves, and (3) measured noise patterns. Tissue attenuation curves were measured in patient data using regions of interest in gray matter and white matter. By assigning the tissue attenuation curves to the corresponding tissue curves within the phantom, patient‐specific CTP acquisitions were retrospectively simulated. Noise patterns were acquired by repeatedly scanning an anthropomorphic skull phantom at various exposure settings. The authors selected 20 consecutive patients that were scanned for suspected ischemic stroke and constructed patient‐specific 4D digital phantoms using the individual patients' hemodynamics. The perfusion maps of the patient data were compared withAbstract : Purpose: Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data, and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters. The authors expand this idea by using realistic noise patterns and measured tissue attenuation curves representing patient‐specific hemodynamics. The purpose of this work is to validate that this approach can realistically simulate mean perfusion values and noise on perfusion data for individual patients. Methods: The proposed 4D digital phantom consists of three major components: (1) a definition of the spatial structure of various brain tissues within the phantom, (2) measured tissue attenuation curves, and (3) measured noise patterns. Tissue attenuation curves were measured in patient data using regions of interest in gray matter and white matter. By assigning the tissue attenuation curves to the corresponding tissue curves within the phantom, patient‐specific CTP acquisitions were retrospectively simulated. Noise patterns were acquired by repeatedly scanning an anthropomorphic skull phantom at various exposure settings. The authors selected 20 consecutive patients that were scanned for suspected ischemic stroke and constructed patient‐specific 4D digital phantoms using the individual patients' hemodynamics. The perfusion maps of the patient data were compared with the digital phantom data. Agreement between phantom‐ and patient‐derived data was determined for mean perfusion values and for standard deviation in de perfusion data using intraclass correlation coefficients (ICCs) and a linear fit. Results: ICCs ranged between 0.92 and 0.99 for mean perfusion values. ICCs for the standard deviation in perfusion maps were between 0.86 and 0.93. Linear fitting yielded slope values between 0.90 and 1.06. Conclusions: A patient‐specific 4D digital phantom allows for realistic simulation of mean values and standard deviation in perfusion data and makes it possible to retrospectively study how the interaction of patient hemodynamics and scan parameters affects CT perfusion values. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 7(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 7(2014)
- Issue Display:
- Volume 41, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 7
- Issue Sort Value:
- 2014-0041-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-06-12
- Subjects:
- Computed tomography -- Noise in the nervous system -- Blood‐brain barrier -- Noise
biological tissues -- brain -- computerised tomography -- haemodynamics -- image denoising -- medical image processing -- phantoms
digital phantom -- CT perfusion -- brain perfusion -- 4DCT
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Image enhancement or restoration, e.g. from bit‐mapped to bit‐mapped creating a similar image
Medical image noise -- Tissues -- Computed tomography -- Brain -- Haemodynamics -- Computer software -- Stroke -- Image scanners -- Medical image reconstruction
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4881520 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9318.xml