Influence of myopotential interference on the Wavelet discrimination algorithm in implantable cardioverter‐defibrillator. Issue 3 (1st October 2016)
- Record Type:
- Journal Article
- Title:
- Influence of myopotential interference on the Wavelet discrimination algorithm in implantable cardioverter‐defibrillator. Issue 3 (1st October 2016)
- Main Title:
- Influence of myopotential interference on the Wavelet discrimination algorithm in implantable cardioverter‐defibrillator
- Authors:
- Mizukami, Kazuya
Yokoshiki, Hisashi
Mitsuyama, Hirofumi
Watanabe, Masaya
Tenma, Taro
Kamada, Rui
Takahashi, Masayuki
Sasaki, Ryo
Maeno, Motoki
Tsutsui, Hiroyuki - Abstract:
- Abstract: Background: Wavelet is a morphology‐based algorithm for detecting ventricular tachycardia. The electrogram (EGM) source of the Wavelet algorithm is nominally programmed with the Can‐RV coil configuration, which records a far‐field ventricular potential. Therefore, it may be influenced by myopotential interference. Methods: We performed a retrospective review of 40 outpatients who had an implantable cardioverter‐defibrillator (ICD) with the Wavelet algorithm. The percent‐match score of the Wavelet algorithm was measured during the isometric chest press by pressing the palms together. We classified patients with percent‐match scores below 70% due to myopotential interference as positive morphology change, and those with 70% or more as negative morphology change. Stored episodes of tachycardia were evaluated during the follow‐up. Results: The number of patients in the positive morphology change group was 22 (55%). Amplitude of the Can‐RV coil EGM was lower in the positive morphology change group compared to that in the negative group (3.9±1.3 mV vs. 7.4±1.6 mV, P =0.0015). The cut‐off value of the Can‐RV coil EGM was 5 mV (area under curve, 0.89). Inappropriate detections caused by myopotential interference occurred in two patients (5%) during a mean follow‐up period of 49 months, and one of them received an inappropriate ICD shock. These patients had exhibited positive morphology change. Conclusions: The Wavelet algorithm is influenced by myopotential interferenceAbstract: Background: Wavelet is a morphology‐based algorithm for detecting ventricular tachycardia. The electrogram (EGM) source of the Wavelet algorithm is nominally programmed with the Can‐RV coil configuration, which records a far‐field ventricular potential. Therefore, it may be influenced by myopotential interference. Methods: We performed a retrospective review of 40 outpatients who had an implantable cardioverter‐defibrillator (ICD) with the Wavelet algorithm. The percent‐match score of the Wavelet algorithm was measured during the isometric chest press by pressing the palms together. We classified patients with percent‐match scores below 70% due to myopotential interference as positive morphology change, and those with 70% or more as negative morphology change. Stored episodes of tachycardia were evaluated during the follow‐up. Results: The number of patients in the positive morphology change group was 22 (55%). Amplitude of the Can‐RV coil EGM was lower in the positive morphology change group compared to that in the negative group (3.9±1.3 mV vs. 7.4±1.6 mV, P =0.0015). The cut‐off value of the Can‐RV coil EGM was 5 mV (area under curve, 0.89). Inappropriate detections caused by myopotential interference occurred in two patients (5%) during a mean follow‐up period of 49 months, and one of them received an inappropriate ICD shock. These patients had exhibited positive morphology change. Conclusions: The Wavelet algorithm is influenced by myopotential interference when the Can‐RV coil EGM is less than 5 mV. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 33:Issue 3(2017)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 33:Issue 3(2017)
- Issue Display:
- Volume 33, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2017-0033-0003-0000
- Page Start:
- 214
- Page End:
- 219
- Publication Date:
- 2016-10-01
- Subjects:
- Implantable cardioverter‐defibrillator -- Tachycardia discrimination -- Morphology -- Myopotential interference -- Wavelet
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2016.08.005 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9303.xml