Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution‐based method to address the volume averaging effect. Issue 5 (4th April 2016)
- Record Type:
- Journal Article
- Title:
- Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution‐based method to address the volume averaging effect. Issue 5 (4th April 2016)
- Main Title:
- Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution‐based method to address the volume averaging effect
- Authors:
- Barraclough, Brendan
Li, Jonathan G.
Lebron, Sharon
Fan, Qiyong
Liu, Chihray
Yan, Guanghua - Abstract:
- Abstract : Purpose: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution‐based method to address the volume averaging effect (VAE). Methods: A convolution‐based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit "real" ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber‐measured profiles and the diode‐measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%–80% penumbra width difference (PWD) between the computed and diode‐measured beam profiles. Results: The convolution‐based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependentAbstract : Purpose: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution‐based method to address the volume averaging effect (VAE). Methods: A convolution‐based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit "real" ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber‐measured profiles and the diode‐measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%–80% penumbra width difference (PWD) between the computed and diode‐measured beam profiles. Results: The convolution‐based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependent DRFs, the PWD was within 0.80 mm for the parabolic function and CC04 combination and within 0.50 mm for other combinations; with geometry independent DRFs, the PWD was within 1.00 mm for all cases. When using the Gaussian function as the DRF, accounting for geometry dependence led to marginal improvement (PWD < 0.20 mm) for CC04; the improvement ranged from 0.38 to 0.65 mm for CC13; for SNC125c, the improvement was slightly above 0.50 mm. Conclusions: Although all three DRFs were found adequate to represent the response of the studied ionization chambers, the Gaussian function was favored due to its superior overall performance. The geometry dependence of the DRFs can be significant for clinical applications involving small fields such as stereotactic radiotherapy. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 5(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 5(2016)
- Issue Display:
- Volume 43, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 5
- Issue Sort Value:
- 2016-0043-0005-0000
- Page Start:
- 2081
- Page End:
- 2086
- Publication Date:
- 2016-04-04
- Subjects:
- biomedical equipment -- ionisation chambers -- optimisation -- radiation therapy
Therapeutic applications, including brachytherapy -- Gas‐filled counters: ionization chambers, proportional, and avalanche counters
Radiation therapy -- Measurement of nuclear or x‐radiation -- Tubes for determining the presence, intensity, density or energy of radiation or particles -- with scintillation detectors -- Ionisation chambers
volume averaging effect -- detector response function -- geometry dependence -- beam modeling
Ionization chambers -- Particle beam detectors -- Dosimetry -- Field size -- Image scanners -- Collective models -- Three dimensional sensing -- Ion beam detectors -- Radiosurgery
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4944783 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9310.xml