Deformable registration of the inflated and deflated lung in cone‐beam CT‐guided thoracic surgery: Initial investigation of a combined model‐ and image‐driven approach. Issue 1 (18th December 2012)
- Record Type:
- Journal Article
- Title:
- Deformable registration of the inflated and deflated lung in cone‐beam CT‐guided thoracic surgery: Initial investigation of a combined model‐ and image‐driven approach. Issue 1 (18th December 2012)
- Main Title:
- Deformable registration of the inflated and deflated lung in cone‐beam CT‐guided thoracic surgery: Initial investigation of a combined model‐ and image‐driven approach
- Authors:
- Uneri, Ali
Nithiananthan, Sajendra
Schafer, Sebastian
Otake, Yoshito
Stayman, J. Webster
Kleinszig, Gerhard
Sussman, Marc S.
Prince, Jerry L.
Siewerdsen, Jeffrey H. - Abstract:
- Abstract : Purpose: : Surgical resection is the preferred modality for curative treatment of early stage lung cancer, but localization of small tumors (<10 mm diameter) during surgery presents a major challenge that is likely to increase as more early‐stage disease is detected incidentally and in low‐dose CT screening. To overcome the difficulty of manual localization (fingers inserted through intercostal ports) and the cost, logistics, and morbidity of preoperative tagging (coil or dye placement under CT‐fluoroscopy), the authors propose the use of intraoperative cone‐beam CT (CBCT) and deformable image registration to guide targeting of small tumors in video‐assisted thoracic surgery (VATS). A novel algorithm is reported for registration of the lung from its inflated state (prior to pleural breach) to the deflated state (during resection) to localize surgical targets and adjacent critical anatomy. Methods: : The registration approach geometrically resolves images of the inflated and deflated lung using a coarse model‐driven stage followed by a finer image‐driven stage. The model‐driven stage uses image features derived from the lung surfaces and airways: triangular surface meshes are morphed to capture bulk motion; concurrently, the airways generate graph structures from which corresponding nodes are identified. Interpolation of the sparse motion fields computed from the bounding surface and interior airways provides a 3D motion field that coarsely registers the lung andAbstract : Purpose: : Surgical resection is the preferred modality for curative treatment of early stage lung cancer, but localization of small tumors (<10 mm diameter) during surgery presents a major challenge that is likely to increase as more early‐stage disease is detected incidentally and in low‐dose CT screening. To overcome the difficulty of manual localization (fingers inserted through intercostal ports) and the cost, logistics, and morbidity of preoperative tagging (coil or dye placement under CT‐fluoroscopy), the authors propose the use of intraoperative cone‐beam CT (CBCT) and deformable image registration to guide targeting of small tumors in video‐assisted thoracic surgery (VATS). A novel algorithm is reported for registration of the lung from its inflated state (prior to pleural breach) to the deflated state (during resection) to localize surgical targets and adjacent critical anatomy. Methods: : The registration approach geometrically resolves images of the inflated and deflated lung using a coarse model‐driven stage followed by a finer image‐driven stage. The model‐driven stage uses image features derived from the lung surfaces and airways: triangular surface meshes are morphed to capture bulk motion; concurrently, the airways generate graph structures from which corresponding nodes are identified. Interpolation of the sparse motion fields computed from the bounding surface and interior airways provides a 3D motion field that coarsely registers the lung and initializes the subsequent image‐driven stage. The image‐driven stage employs an intensity‐corrected, symmetric form of the Demons method. The algorithm was validated over 12 datasets, obtained from porcine specimen experiments emulating CBCT‐guided VATS. Geometric accuracy was quantified in terms of target registration error (TRE) in anatomical targets throughout the lung, and normalized cross‐correlation. Variations of the algorithm were investigated to study the behavior of the model‐ and image‐driven stages by modifying individual algorithmic steps and examining the effect in comparison to the nominal process. Results: : The combined model‐ and image‐driven registration process demonstrated accuracy consistent with the requirements of minimally invasive VATS in both target localization (∼3–5 mm within the target wedge) and critical structure avoidance (∼1–2 mm). The model‐driven stage initialized the registration to within a median TRE of 1.9 mm (95% confidence interval (CI) maximum = 5.0 mm), while the subsequent image‐driven stage yielded higher accuracy localization with 0.6 mm median TRE (95% CI maximum = 4.1 mm). The variations assessing the individual algorithmic steps elucidated the role of each step and in some cases identified opportunities for further simplification and improvement in computational speed. Conclusions: : The initial studies show the proposed registration method to successfully register CBCT images of the inflated and deflated lung. Accuracy appears sufficient to localize the target and adjacent critical anatomy within ∼1–2 mm and guide localization under conditions in which the target cannot be discerned directly in CBCT (e.g., subtle, nonsolid tumors). The ability to directly localize tumors in the operating room could provide a valuable addition to the VATS arsenal, obviate the cost, logistics, and morbidity of preoperative tagging, and improve patient safety. Future work includes in vivo testing, optimization of workflow, and integration with a CBCT image guidance system. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 1(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 1(2013)
- Issue Display:
- Volume 40, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2013-0040-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2012-12-18
- Subjects:
- Computed tomography -- Cancer -- Registration
cancer -- computerised tomography -- image registration -- lung -- medical image processing -- surgery -- tumours -- video equipment
deformable image registration -- image‐guided surgery -- cone‐beam CT -- thoracic surgery -- Demons algorithm -- intraoperative imaging
Computerised tomographs -- Surgical instruments, devices or methods, e.g. tourniquets -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Details of television systems -- Television systems
Lungs -- Medical imaging -- Cone beam computed tomography -- Cancer -- Image registration -- Computed tomography -- Anatomy -- Surface structure -- Testing procedures -- Interpolation
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4767757 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9313.xml