The association between defibrillation shock energy and acute cardiac damage in patients with implantable cardioverter defibrillators. Issue 6 (26th April 2016)
- Record Type:
- Journal Article
- Title:
- The association between defibrillation shock energy and acute cardiac damage in patients with implantable cardioverter defibrillators. Issue 6 (26th April 2016)
- Main Title:
- The association between defibrillation shock energy and acute cardiac damage in patients with implantable cardioverter defibrillators
- Authors:
- Ishigaki, Daisuke
Kutsuzawa, Daisuke
Arimoto, Takanori
Iwayama, Tadateru
Hashimoto, Naoaki
Kumagai, Yu
Nishiyama, Satoshi
Takahashi, Hiroki
Shishido, Tetsuro
Miyamoto, Takuya
Nitobe, Joji
Fukui, Akio
Watanabe, Tetsu
Kubota, Isao - Abstract:
- Abstract: Background: The aim of this study was to establish a minimally invasive defibrillation testing (DT) protocol for patients with implantable cardioverter defibrillators (ICDs). Methods: Two different energy DTs were performed, immediately after (15 J‐DT) and 7 days after (≤10 J‐DT) device implantation, in 20 consecutive ICD implantation patients. Cardiac‐troponin T (c‐TNT) and heart‐type fatty acid binding protein (H‐FABP) levels were measured before implantation, 2 h after implantation, and 1 day after each DT. For an additional 122 patients with ICD, we retrospectively analyzed 203 DTs immediately and 7 days after device implantation. Results: Serum c‐TNT levels were significantly elevated 2 h after 15 J‐DT [0.008 (0.004–0.019) vs. 0.053 (0.037–0.068) ng/mL, p <0.001], but not ≤10 J‐DT [0.007 (0.004–0.018) ng/mL]. Similarly, serum H‐FABP levels were significantly elevated 2 h after 15 J‐DT (2.9±1.5 vs. 6.4±3.4 ng/mL, p <0.001), but not ≤10 J‐DT (2.7±1.5 ng/mL). The changes in c‐TNT and H‐FABP levels between baseline and 2 h after DT were significantly greater for 15 J‐DT compared with ≤10 J‐DT [c‐TnT: 0.039 (0.029–0.060) vs. 0 (0–0.003) ng/mL, p <0.001; H‐FABP: 3.6±2.8 vs. −0.16±1.1 ng/mL, p <0.001]. The success rates of the initial shocks delivered for ventricular fibrillation were no different between ≤10 J‐DT (85% [78/92]) and ≥15 J‐DT (92% [103/111]). Conclusions: Elevated levels of myocardial damage markers such as c‐TNT and H‐FABP were not found after ≤10Abstract: Background: The aim of this study was to establish a minimally invasive defibrillation testing (DT) protocol for patients with implantable cardioverter defibrillators (ICDs). Methods: Two different energy DTs were performed, immediately after (15 J‐DT) and 7 days after (≤10 J‐DT) device implantation, in 20 consecutive ICD implantation patients. Cardiac‐troponin T (c‐TNT) and heart‐type fatty acid binding protein (H‐FABP) levels were measured before implantation, 2 h after implantation, and 1 day after each DT. For an additional 122 patients with ICD, we retrospectively analyzed 203 DTs immediately and 7 days after device implantation. Results: Serum c‐TNT levels were significantly elevated 2 h after 15 J‐DT [0.008 (0.004–0.019) vs. 0.053 (0.037–0.068) ng/mL, p <0.001], but not ≤10 J‐DT [0.007 (0.004–0.018) ng/mL]. Similarly, serum H‐FABP levels were significantly elevated 2 h after 15 J‐DT (2.9±1.5 vs. 6.4±3.4 ng/mL, p <0.001), but not ≤10 J‐DT (2.7±1.5 ng/mL). The changes in c‐TNT and H‐FABP levels between baseline and 2 h after DT were significantly greater for 15 J‐DT compared with ≤10 J‐DT [c‐TnT: 0.039 (0.029–0.060) vs. 0 (0–0.003) ng/mL, p <0.001; H‐FABP: 3.6±2.8 vs. −0.16±1.1 ng/mL, p <0.001]. The success rates of the initial shocks delivered for ventricular fibrillation were no different between ≤10 J‐DT (85% [78/92]) and ≥15 J‐DT (92% [103/111]). Conclusions: Elevated levels of myocardial damage markers such as c‐TNT and H‐FABP were not found after ≤10 J‐DT. In addition, an acceptable success rate was confirmed in ≤10 J‐DT. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 32:Issue 6(2016)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 32:Issue 6(2016)
- Issue Display:
- Volume 32, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 6
- Issue Sort Value:
- 2016-0032-0006-0000
- Page Start:
- 481
- Page End:
- 485
- Publication Date:
- 2016-04-26
- Subjects:
- Implantable cardioverter defibrillator -- Defibrillation test -- Myocardial injury -- Heart‐type fatty acid binding protein -- Troponin T
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2016.03.007 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9303.xml