Correction of MRI‐induced geometric distortions in whole‐body small animal PET‐MRI. Issue 7 (9th June 2015)
- Record Type:
- Journal Article
- Title:
- Correction of MRI‐induced geometric distortions in whole‐body small animal PET‐MRI. Issue 7 (9th June 2015)
- Main Title:
- Correction of MRI‐induced geometric distortions in whole‐body small animal PET‐MRI
- Authors:
- Frohwein, Lynn J.
Hoerr, Verena
Faber, Cornelius
Schäfers, Klaus P. - Abstract:
- Abstract : Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole‐body PET‐MRI. The quality of the registration between these two modalities in large field‐of‐views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin‐plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could beAbstract : Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole‐body PET‐MRI. The quality of the registration between these two modalities in large field‐of‐views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin‐plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point‐based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole‐body small animal imaging routines including different standard MRI sequences. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 7(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 7(2015)
- Issue Display:
- Volume 42, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2015-0042-0007-0000
- Page Start:
- 3848
- Page End:
- 3858
- Publication Date:
- 2015-06-09
- Subjects:
- biomedical MRI -- data acquisition -- distortion measurement -- geometry -- image registration -- medical image processing -- phantoms -- positron emission tomography
Magnetic resonance imaging -- Positron emission tomography (PET) -- Registration
Involving electronic [emr] or nuclear [nmr] magnetic resonance, e.g. magnetic resonance imaging -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Scintigraphy -- Measuring half‐life of a radioactive substance
gradient nonlinearity -- PET‐MRI -- distortion correction -- phantom -- preclinical imaging
Magnetic resonance imaging -- Positron emission tomography -- Three dimensional image processing -- Magnetic fields -- Image scanners -- Magnetic materials -- Medical image spatial resolution -- Process monitoring and control
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4921418 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9310.xml