Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy. Issue 9 (3rd September 2013)
- Record Type:
- Journal Article
- Title:
- Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy. Issue 9 (3rd September 2013)
- Main Title:
- Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy
- Authors:
- Helmbrecht, Stephan
Enghardt, Wolfgang
Parodi, Katia
Didinger, Bernd
Debus, Jürgen
Kunath, Daniela
Priegnitz, Marlen
Fiedler, Fine - Abstract:
- Abstract : Purpose: : Particle Therapy Positron Emission Tomography (PT‐PET) is a suitable method for verification of therapeutic dose delivery by measurements of irradiation‐induced β + ‐activity. Due to metabolic processes in living tissue β + ‐emitters can be removed from the place of generation. This washout is a limiting factor for image quality. The purpose of this study is to investigate whether a washout model obtained by animal experiments is applicable to patient data. Methods: : A model for the washout has been developed by Mizuno et al. [Phys. Med. Biol. 48(15), – (2003)]10.1088/0031‐9155/48/15/302 and Tomitani et al. [Phys. Med. Biol. 48(7), 875–889 (2003)]10.1088/0031‐9155/48/7/305 . It is based upon measurements in a rabbit in living and dead conditions. This model was modified and applied to PET data acquired during the experimental therapy project at GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, Germany. Three components are expected: A fast one with a half life of 2 s, a medium one in the range of 2–3 min, and a slow component of the order of 2–3 h. Ten patients were selected randomly for investigation of the fast component. To analyze the other two components, 12 one‐of‐a‐kind measurements from a single volunteer patient are available. Results: : A fast washout on the time scale of a few seconds was not observed in the patient data. The medium processes showed a mean half life of 155.7 ± 4.6 s. This is in the expected range. Fractions of theAbstract : Purpose: : Particle Therapy Positron Emission Tomography (PT‐PET) is a suitable method for verification of therapeutic dose delivery by measurements of irradiation‐induced β + ‐activity. Due to metabolic processes in living tissue β + ‐emitters can be removed from the place of generation. This washout is a limiting factor for image quality. The purpose of this study is to investigate whether a washout model obtained by animal experiments is applicable to patient data. Methods: : A model for the washout has been developed by Mizuno et al. [Phys. Med. Biol. 48(15), – (2003)]10.1088/0031‐9155/48/15/302 and Tomitani et al. [Phys. Med. Biol. 48(7), 875–889 (2003)]10.1088/0031‐9155/48/7/305 . It is based upon measurements in a rabbit in living and dead conditions. This model was modified and applied to PET data acquired during the experimental therapy project at GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, Germany. Three components are expected: A fast one with a half life of 2 s, a medium one in the range of 2–3 min, and a slow component of the order of 2–3 h. Ten patients were selected randomly for investigation of the fast component. To analyze the other two components, 12 one‐of‐a‐kind measurements from a single volunteer patient are available. Results: : A fast washout on the time scale of a few seconds was not observed in the patient data. The medium processes showed a mean half life of 155.7 ± 4.6 s. This is in the expected range. Fractions of the activity not influenced by the washout were found. Conclusions: : On the time scale of an in‐beam or in‐room measurement only the medium‐time washout processes play a remarkable role. A slow component may be neglected if the measurements do not exceed 20 min after the end of the irradiation. The fast component is not observed due to the low relative blood filled volume in the brain. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 9(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 9(2013)
- Issue Display:
- Volume 40, Issue 9 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 9
- Issue Sort Value:
- 2013-0040-0009-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-09-03
- Subjects:
- Dose‐volume analysis -- Quality assurance in radiotherapy -- Image quality -- Positron emission tomography (PET) -- Dosimetry -- Dosimetry/exposure assessment
brain -- data acquisition -- dosimetry -- positron emission tomography -- radiation therapy
in‐beam PET -- ion beam therapy -- in vivo dosimetry -- positron emitter washout
Radiation therapy -- Biological material, e.g. blood, urine; Haemocytometers -- Scintigraphy -- Measuring half‐life of a radioactive substance
Positron emission tomography -- Positrons -- Medical imaging -- Tissues -- Carbon -- Calcium -- Therapeutics -- Brain -- Dosimetry -- Biomedical modeling
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4818424 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9304.xml