Multivariate analysis for the estimation of target localization errors in fiducial marker‐based radiotherapy. Issue 4 (24th March 2016)
- Record Type:
- Journal Article
- Title:
- Multivariate analysis for the estimation of target localization errors in fiducial marker‐based radiotherapy. Issue 4 (24th March 2016)
- Main Title:
- Multivariate analysis for the estimation of target localization errors in fiducial marker‐based radiotherapy
- Authors:
- Takamiya, Masanori
Nakamura, Mitsuhiro
Akimoto, Mami
Ueki, Nami
Yamada, Masahiro
Tanabe, Hiroaki
Matsuo, Yukinori
Mizowaki, Takashi
Kokubo, Masaki
Hiraoka, Masahiro
Itoh, Akio - Abstract:
- Abstract : Purpose: To assess the target localization error (TLE) in terms of the distance between the target and the localization point estimated from the surrogates (|TMD|), the average of respiratory motion for the surrogates and the target (|aRM|), and the number of fiducial markers used for estimating the target ( n ). Methods: This study enrolled 17 lung cancer patients who subsequently underwent four fractions of real‐time tumor tracking irradiation. Four or five fiducial markers were implanted around the lung tumor. The three‐dimensional (3D) distance between the tumor and markers was at maximum 58.7 mm. One of the markers was used as the target ( Pt ), and those markers with a 3D |TMD n | ≤ 58.7 mm at end‐exhalation were then selected. The estimated target position ( Pe ) was calculated from a localization point consisting of one to three markers except Pt . Respiratory motion for Pt and Pe was defined as the root mean square of each displacement, and |aRM| was calculated from the mean value. TLE was defined as the root mean square of each difference between Pt and Pe during the monitoring of each fraction. These procedures were performed repeatedly using the remaining markers. To provide the best guidance on the answer with n and |TMD|, fiducial markers with a 3D |aRM ≥ 10 mm were selected. Finally, a total of 205, 282, and 76 TLEs that fulfilled the 3D |TMD| and 3D |aRM| criteria were obtained for n = 1, 2, and 3, respectively. Multiple regression analysis (MRA)Abstract : Purpose: To assess the target localization error (TLE) in terms of the distance between the target and the localization point estimated from the surrogates (|TMD|), the average of respiratory motion for the surrogates and the target (|aRM|), and the number of fiducial markers used for estimating the target ( n ). Methods: This study enrolled 17 lung cancer patients who subsequently underwent four fractions of real‐time tumor tracking irradiation. Four or five fiducial markers were implanted around the lung tumor. The three‐dimensional (3D) distance between the tumor and markers was at maximum 58.7 mm. One of the markers was used as the target ( Pt ), and those markers with a 3D |TMD n | ≤ 58.7 mm at end‐exhalation were then selected. The estimated target position ( Pe ) was calculated from a localization point consisting of one to three markers except Pt . Respiratory motion for Pt and Pe was defined as the root mean square of each displacement, and |aRM| was calculated from the mean value. TLE was defined as the root mean square of each difference between Pt and Pe during the monitoring of each fraction. These procedures were performed repeatedly using the remaining markers. To provide the best guidance on the answer with n and |TMD|, fiducial markers with a 3D |aRM ≥ 10 mm were selected. Finally, a total of 205, 282, and 76 TLEs that fulfilled the 3D |TMD| and 3D |aRM| criteria were obtained for n = 1, 2, and 3, respectively. Multiple regression analysis (MRA) was used to evaluate TLE as a function of |TMD| and |aRM| in each n . Results: |TMD| for n = 1 was larger than that for n = 3. Moreover, |aRM| was almost constant for all n, indicating a similar scale for the marker's motion near the lung tumor. MRA showed that |aRM| in the left–right direction was the major cause of TLE; however, the contribution made little difference to the 3D TLE because of the small amount of motion in the left–right direction. The TLE calculated from the MRA ( MRA TLE) increased as |TMD| and |aRM| increased and adversely decreased with each increment of n . The median 3D MRA TLE was 2.0 mm (range, 0.6–4.3 mm) for n = 1, 1.8 mm (range, 0.4–4.0 mm) for n = 2, and 1.6 mm (range, 0.3–3.7 mm) for n = 3. Although statistical significance between n = 1 and n = 3 was observed in all directions, the absolute average difference and the standard deviation of the MRA TLE between n = 1 and n = 3 were 0.5 and 0.2 mm, respectively. Conclusions: A large |TMD| and |aRM| increased the differences in TLE between each n ; however, the difference in 3D MRA TLEs was, at most, 0.6 mm. Thus, the authors conclude that it is acceptable to continue fiducial marker‐based radiotherapy as long as |TMD| is maintained at ≤58.7 mm for a 3D |aRM| ≥ 10 mm. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 4(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 4(2016)
- Issue Display:
- Volume 43, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2016-0043-0004-0000
- Page Start:
- 1907
- Page End:
- 1912
- Publication Date:
- 2016-03-24
- Subjects:
- cancer -- error analysis -- lung -- mean square error methods -- pneumodynamics -- regression analysis -- variational techniques
Pneumodyamics, respiration -- Cancer -- General statistical methods -- Probability theory, stochastic processes, and statistics -- Numerical approximation and analysis
fiducial marker‐based radiotherapy -- dynamic tumor tracking -- respiratory gating -- target localization error
Cancer -- Lungs -- Dosimetry -- Medical X‐ray imaging -- X‐ray imaging -- Three dimensional image processing -- Error analysis -- Tissues
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4944594 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9315.xml