Prevention of pressure ulcers with a static air support surface: A systematic review. Issue 3 (5th March 2018)
- Record Type:
- Journal Article
- Title:
- Prevention of pressure ulcers with a static air support surface: A systematic review. Issue 3 (5th March 2018)
- Main Title:
- Prevention of pressure ulcers with a static air support surface: A systematic review
- Authors:
- Serraes, Brecht
van Leen, Martin
Schols, Jos
Van Hecke, Ann
Verhaeghe, Sofie
Beeckman, Dimitri - Abstract:
- Abstract : The aims of this study were to identify, assess, and summarise available evidence about the effectiveness of static air mattress overlays to prevent pressure ulcers. The primary outcome was the incidence of pressure ulcers. Secondary outcomes included costs and patient comfort. This study was a systematic review. Six electronic databases were consulted: Cochrane Library, EMBASE, PubMed (Medline), CINAHL (EBSCOhost interface), Science direct, and Web of Science. In addition, a hand search through reviews, conference proceedings, and the reference lists of the included studies was performed to identify additional studies. Potential studies were reviewed and assessed by 2 independent authors based on the title and abstract. Decisions regarding inclusion or exclusion of the studies were based on a consensus between the authors. Studies were included if the following criteria were met: reporting an original study; the outcome was the incidence of pressure ulcer categories I to IV when using a static air mattress overlay and/or in comparison with other pressure‐redistribution device(s); and studies published in English, French, and Dutch. No limitation was set on study setting, design, and date of publication. The methodological quality assessment was evaluated using the Critical Appraisal Skills Program Tool. Results were reported in a descriptive way to reflect the exploratory nature of the review. The searches included 13 studies: randomised controlled trials ( n =Abstract : The aims of this study were to identify, assess, and summarise available evidence about the effectiveness of static air mattress overlays to prevent pressure ulcers. The primary outcome was the incidence of pressure ulcers. Secondary outcomes included costs and patient comfort. This study was a systematic review. Six electronic databases were consulted: Cochrane Library, EMBASE, PubMed (Medline), CINAHL (EBSCOhost interface), Science direct, and Web of Science. In addition, a hand search through reviews, conference proceedings, and the reference lists of the included studies was performed to identify additional studies. Potential studies were reviewed and assessed by 2 independent authors based on the title and abstract. Decisions regarding inclusion or exclusion of the studies were based on a consensus between the authors. Studies were included if the following criteria were met: reporting an original study; the outcome was the incidence of pressure ulcer categories I to IV when using a static air mattress overlay and/or in comparison with other pressure‐redistribution device(s); and studies published in English, French, and Dutch. No limitation was set on study setting, design, and date of publication. The methodological quality assessment was evaluated using the Critical Appraisal Skills Program Tool. Results were reported in a descriptive way to reflect the exploratory nature of the review. The searches included 13 studies: randomised controlled trials ( n = 11) and cohort studies ( n = 2). The mean pressure ulcer incidence figures found in the different settings were, respectively, 7.8% pressure ulcers of categories II to IV in nursing homes, 9.06% pressure ulcers of categories I to IV in intensive care settings, and 12% pressure ulcers of categories I to IV in orthopaedic wards. Seven comparative studies reported a lower incidence in the groups of patients on a static air mattress overlay. Three studies reported a statistical ( P < .1) lower incidence compared with a standard hospital mattress (10 cm thick, density 35 kg/m 3 ), a foam mattress (15 cm thick), and a viscoelastic foam mattress (15 cm thick). No significant difference in incidence, purchase costs, and patient comfort was found compared with dynamic air mattresses. This review focused on the effectiveness of static air mattress overlays to prevent pressure ulcers. There are indications that these mattress overlays are more effective in preventing pressure ulcers compared with the use of a standard mattress or a pressure‐reducing foam mattress in nursing homes and intensive care settings. However, interpretation of the evidence should be performed with caution due to the wide variety of methodological and/or reporting quality levels of the included studies. … (more)
- Is Part Of:
- International wound journal. Volume 15:Issue 3(2018)
- Journal:
- International wound journal
- Issue:
- Volume 15:Issue 3(2018)
- Issue Display:
- Volume 15, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 15
- Issue:
- 3
- Issue Sort Value:
- 2018-0015-0003-0000
- Page Start:
- 333
- Page End:
- 343
- Publication Date:
- 2018-03-05
- Subjects:
- incidence -- low‐technology support surfaces -- pressure ulcers -- prevention -- static air support surfaces
Wounds and injuries -- Treatment -- Periodicals
Wounds and injuries -- Periodicals
Wound healing -- Periodicals
617.1005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1742-481X ↗
http://search.ebscohost.com/login.aspx?direct=true&db=rzh&jid=1725&site=ehost-live ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=iwj ↗
http://www3.interscience.wiley.com/journal/117982033/home ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/iwj.12870 ↗
- Languages:
- English
- ISSNs:
- 1742-4801
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4552.230800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9298.xml