Bleeding and thrombotic events occur early in children on durable ventricular assist devices. Issue 173 (January 2019)
- Record Type:
- Journal Article
- Title:
- Bleeding and thrombotic events occur early in children on durable ventricular assist devices. Issue 173 (January 2019)
- Main Title:
- Bleeding and thrombotic events occur early in children on durable ventricular assist devices
- Authors:
- Huang, Joanna Y.
Ignjatovic, Vera
Sheridan, Bennett J.
Mathew, Jacob
D'Udekem, Yves
Brink, Johann
Barton, Rebecca
Callea, Gabrielle
Morsman, Dominique
Donath, Susan
Opat, Stephen
Monagle, Paul - Abstract:
- Abstract: Introduction: Durable Ventricular Assist Devices (VADs) are increasingly used in children with end-stage heart failure. Major complications are bleeding and thromboembolism (TE). Our objective was to determine the timing, incidence and risk factors for bleeding and TE in children implanted with VADs. Methods: This was a retrospective cohort of 8 years experience for children implanted with HeartWare HVAD and Berlin Heart EXCOR VADs at the Royal Children's Hospital, Melbourne. Results: 44 patients were implanted with Berlin Heart EXCOR or HeartWare HVAD devices. Major bleeding occurred in 17 patients (39%), 7 (16%) experienced thromboembolic strokes, 13 (30%) required device exchange for TE, and 4 (9%) experienced arterial thromboembolism. Twenty-seven patients (61%) were transplanted, three (7%) recovered, and six (14%) remain on device when censored. Eight patients (18%) died on VAD, with leading causes being thromboembolic stroke and intracranial bleeding. The majority of bleeding events and thromboembolic events occurred while patients were on unfractionated heparin (bleeding 66%, TE 40.5%) or transitioning between heparin and warfarin (bleeding 22%, TE 38%). Majority of patients were on more than one antiplatelet agent at the time of a major bleeding (87%) or thromboembolic (89%) event. Conclusions: The majority of bleeding and TE events occurring in children supported with durable VADs occur when they are on unfractionated heparin or transitioning to warfarin.Abstract: Introduction: Durable Ventricular Assist Devices (VADs) are increasingly used in children with end-stage heart failure. Major complications are bleeding and thromboembolism (TE). Our objective was to determine the timing, incidence and risk factors for bleeding and TE in children implanted with VADs. Methods: This was a retrospective cohort of 8 years experience for children implanted with HeartWare HVAD and Berlin Heart EXCOR VADs at the Royal Children's Hospital, Melbourne. Results: 44 patients were implanted with Berlin Heart EXCOR or HeartWare HVAD devices. Major bleeding occurred in 17 patients (39%), 7 (16%) experienced thromboembolic strokes, 13 (30%) required device exchange for TE, and 4 (9%) experienced arterial thromboembolism. Twenty-seven patients (61%) were transplanted, three (7%) recovered, and six (14%) remain on device when censored. Eight patients (18%) died on VAD, with leading causes being thromboembolic stroke and intracranial bleeding. The majority of bleeding events and thromboembolic events occurred while patients were on unfractionated heparin (bleeding 66%, TE 40.5%) or transitioning between heparin and warfarin (bleeding 22%, TE 38%). Majority of patients were on more than one antiplatelet agent at the time of a major bleeding (87%) or thromboembolic (89%) event. Conclusions: The majority of bleeding and TE events occurring in children supported with durable VADs occur when they are on unfractionated heparin or transitioning to warfarin. Modifications to anticoagulation and monitoring in the early post-operative periods should be a research focus. Highlights: Bleeding and clotting risk is highest initially following pediatric VAD insertion. Another high-risk period is the transition between UFH and warfarin. Optimal strategies for anticoagulation are yet to be found during high-risk periods. Majority of thromboembolisms occurred despite patients being on antiplatelet therapy. … (more)
- Is Part Of:
- Thrombosis research. Issue 173(2019)
- Journal:
- Thrombosis research
- Issue:
- Issue 173(2019)
- Issue Display:
- Volume 173, Issue 173 (2019)
- Year:
- 2019
- Volume:
- 173
- Issue:
- 173
- Issue Sort Value:
- 2019-0173-0173-0000
- Page Start:
- 65
- Page End:
- 70
- Publication Date:
- 2019-01
- Subjects:
- aPTT activated partial thromboplastin time -- BHE Berlin Heart EXCOR -- HF heart failure -- INR International Normalized Ratio -- LMWH Low Molecular Weight Heparin -- PRBC packed red blood cells -- SD standard deviation -- TE thromboembolism -- UFH unfractionated heparin -- VAD Ventricular Assist Device
Ventricular assist device -- Mechanical circulatory support -- Pediatrics -- Heart failure -- Thrombosis -- Bleeding
Thrombosis -- Periodicals
616.135 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00493848 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.thromres.2018.11.019 ↗
- Languages:
- English
- ISSNs:
- 0049-3848
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.365000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9293.xml