Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study. (January 2019)
- Record Type:
- Journal Article
- Title:
- Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study. (January 2019)
- Main Title:
- Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study
- Authors:
- Le, Louise
Jabran, Ali
Peach, Chris
Ren, Lei - Abstract:
- Highlights: Full-length threading of a screw can increase varus bending stiffness of a locking plate construct by 4.55%. Inferior three screws exhibited a larger increase in stiffness than superior three. For inferior three screws, 50% threading achieves most mechanical benefits of threading. For superior three screws, 100% threading is required instead. Abstract: Plate-based treatment of proximal humerus fractures is associated with a high risk of complications such as screw perforation into glenohumeral joint. Smooth and threaded pegs were developed with the hope of minimising these risks. No consensus exists onto which threading profile achieves stiffest bone-plate construct. This study investigated the biomechanical effect of five percentages of threading on individual humeral head screws on a bone-plate construct. A finite element model simulating a two-part proximal humerus fracture treated with a Spatial Subchondral Support plate was developed and validated against in vitro biomechanical tests. The proportion of the humeral head screw length that was threaded was varied between 0%-100% in 25% increments. A 5-mm cantilever varus displacement was applied and the required load ( F 5 ) was calculated. Full (100%) threading achieved the stiffest construct for all six screws. Fully threading all smooth pegs at once increased F 5 by 18%. Threading did not increase F 5 equally in all screws. Inferior three plate screws exhibited a larger increase in stiffness than superiorHighlights: Full-length threading of a screw can increase varus bending stiffness of a locking plate construct by 4.55%. Inferior three screws exhibited a larger increase in stiffness than superior three. For inferior three screws, 50% threading achieves most mechanical benefits of threading. For superior three screws, 100% threading is required instead. Abstract: Plate-based treatment of proximal humerus fractures is associated with a high risk of complications such as screw perforation into glenohumeral joint. Smooth and threaded pegs were developed with the hope of minimising these risks. No consensus exists onto which threading profile achieves stiffest bone-plate construct. This study investigated the biomechanical effect of five percentages of threading on individual humeral head screws on a bone-plate construct. A finite element model simulating a two-part proximal humerus fracture treated with a Spatial Subchondral Support plate was developed and validated against in vitro biomechanical tests. The proportion of the humeral head screw length that was threaded was varied between 0%-100% in 25% increments. A 5-mm cantilever varus displacement was applied and the required load ( F 5 ) was calculated. Full (100%) threading achieved the stiffest construct for all six screws. Fully threading all smooth pegs at once increased F 5 by 18%. Threading did not increase F 5 equally in all screws. Inferior three plate screws exhibited a larger increase in stiffness than superior three. Most of the mechanical benefits of threading in inferior three screws can be achieved by using threaded pegs (50% threading) while the superior three screws need to be fully threaded. In practice, the smooth surface profile may also offer additional mechanical benefits if implanted with longer lengths and larger diameters. Threading is an effective way of increasing the varus bending stiffness of proximal humerus plates constructs. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 63(2019)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 63(2019)
- Issue Display:
- Volume 63, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 63
- Issue:
- 2019
- Issue Sort Value:
- 2019-0063-2019-0000
- Page Start:
- 79
- Page End:
- 87
- Publication Date:
- 2019-01
- Subjects:
- Proximal humerus plates -- Finite element analysis -- Screw Threading -- Varus Bending -- Stiffness
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2018.12.004 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9292.xml