Automatic rib cage unfolding with CT cylindrical projection reformat in polytraumatized patients for rib fracture detection and characterization: Feasibility and clinical application. Issue 110 (January 2019)
- Record Type:
- Journal Article
- Title:
- Automatic rib cage unfolding with CT cylindrical projection reformat in polytraumatized patients for rib fracture detection and characterization: Feasibility and clinical application. Issue 110 (January 2019)
- Main Title:
- Automatic rib cage unfolding with CT cylindrical projection reformat in polytraumatized patients for rib fracture detection and characterization: Feasibility and clinical application
- Authors:
- Urbaneja, Ayla
De Verbizier, Jacques
Formery, Anne-Sophie
Tobon-Gomez, Catalina
Nace, Lionel
Blum, Alain
Gondim Teixeira, Pedro Augusto - Abstract:
- Abstract: Objectives: To assess the use of CT with unfolded cylindrical projection (UCP) for rib fracture detection and characterization. Methods: The images from 60 polytraumatized patients who underwent whole body CT were evaluated for the presence and characterization of rib fractures (displaced or not, single or multiple). Two readers independently evaluated conventional CT images and UCP images in two readout sessions at least one month apart. All readouts were timed. A gold standard was established by two radiologists with 12 and 22 years of clinical experience based on the combined analysis of conventional and UCP reformats. Results: Using UCP, the mean evaluation time was 27%–54% shorter ( P = 0.01 and <0.0001) while maintaining a comparable diagnostic performance (sensitivity and specificity of 68.4–79.1% and 99.5–99.6% for conventional reformats and 70.6–91.0% and 96.8–97.7% for UCP) and a good reproducibility (Kappa of 0.71). The multiple fracture detection ratio of UCP was similar to that of conventional reformats (>80%). There were more false positives and false negatives using UCP and displaced fractures were harder to characterize. Conclusion: UCP yielded a diagnostic performance similar to that of conventional reformats for the detection of rib fractures with a good reproducibility and a noticeable reduction in evaluation time.
- Is Part Of:
- European journal of radiology. Issue 110(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 110(2019)
- Issue Display:
- Volume 110, Issue 110 (2019)
- Year:
- 2019
- Volume:
- 110
- Issue:
- 110
- Issue Sort Value:
- 2019-0110-0110-0000
- Page Start:
- 121
- Page End:
- 127
- Publication Date:
- 2019-01
- Subjects:
- Rib cage -- Image processing -- Rib fractures -- Multiple trauma -- Computed tomography
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.11.011 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9292.xml