Reducing radiation exposure by lowering frame rate in children undergoing cardiac catheterization: A quality improvement study. (2nd October 2018)
- Record Type:
- Journal Article
- Title:
- Reducing radiation exposure by lowering frame rate in children undergoing cardiac catheterization: A quality improvement study. (2nd October 2018)
- Main Title:
- Reducing radiation exposure by lowering frame rate in children undergoing cardiac catheterization: A quality improvement study
- Authors:
- Amdani, Shahnawaz M.
Ross, Robert D.
Webster, Paul A.
Turner, Daniel R.
Forbes, Thomas J.
Kobayashi, Daisuke - Abstract:
- Abstract: Introduction: Reduction of radiation dosage in the pediatric cardiac catheterization laboratory (PCL) is important to reduce the risk of its stochastic effect in children with congenital heart disease. Lowering the frame rate would reduce radiation dosage possibly at the expense of image quality, potentially resulting in higher fluoroscopic time and procedural complication rate. Methods: The data were retrospectively analyzed in three eras: era 1 ( n = 234), cineangiography 30 frames/sec (f/s) and fluoroscopy 15 pulse/sec (p/s); era 2 ( n = 381), cineangiography 30 f/s and fluoroscopy 6 p/s; and era 3 ( n = 328), cineangiography 15 f/s and fluoroscopy 6 p/s. Also, three operators blinded to the frame rate setting evaluated cineangiography image quality. In this study, the impact of lowering the default frame rates on radiation dosage, fluoroscopic time, contrast volume, diagnostic image quality, and complication rates in the PCL was assessed. Results: Overall radiation dosage progressively declined during these eras (70.0 vs 64.1 vs 36.6 µGym 2 /kg, P < .001) without a difference in significant adverse event rates. There was no significant increase in either fluoroscopy time or contrast volume. There was no difference in the diagnostic image quality between cineangiography 30 and 15 f/s. Lowering the default frame/pulse rates of both fluoroscopy and cineangiography significantly decreased the overall radiation dosage in the PCL. Importantly, fluoroscopy time,Abstract: Introduction: Reduction of radiation dosage in the pediatric cardiac catheterization laboratory (PCL) is important to reduce the risk of its stochastic effect in children with congenital heart disease. Lowering the frame rate would reduce radiation dosage possibly at the expense of image quality, potentially resulting in higher fluoroscopic time and procedural complication rate. Methods: The data were retrospectively analyzed in three eras: era 1 ( n = 234), cineangiography 30 frames/sec (f/s) and fluoroscopy 15 pulse/sec (p/s); era 2 ( n = 381), cineangiography 30 f/s and fluoroscopy 6 p/s; and era 3 ( n = 328), cineangiography 15 f/s and fluoroscopy 6 p/s. Also, three operators blinded to the frame rate setting evaluated cineangiography image quality. In this study, the impact of lowering the default frame rates on radiation dosage, fluoroscopic time, contrast volume, diagnostic image quality, and complication rates in the PCL was assessed. Results: Overall radiation dosage progressively declined during these eras (70.0 vs 64.1 vs 36.6 µGym 2 /kg, P < .001) without a difference in significant adverse event rates. There was no significant increase in either fluoroscopy time or contrast volume. There was no difference in the diagnostic image quality between cineangiography 30 and 15 f/s. Lowering the default frame/pulse rates of both fluoroscopy and cineangiography significantly decreased the overall radiation dosage in the PCL. Importantly, fluoroscopy time, contrast volume, and complication rates did not increase while maintaining diagnostic image quality. Conclusion: This quality improvement project proved successful in lowering radiation dosage without compromising the efficacy and safety of catheterizations. … (more)
- Is Part Of:
- Congenital heart disease. Volume 13:Number 6(2018)
- Journal:
- Congenital heart disease
- Issue:
- Volume 13:Number 6(2018)
- Issue Display:
- Volume 13, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 13
- Issue:
- 6
- Issue Sort Value:
- 2018-0013-0006-0000
- Page Start:
- 1028
- Page End:
- 1037
- Publication Date:
- 2018-10-02
- Subjects:
- children -- cineangiography -- complication -- fluoroscopy -- frame rate -- radiation dosage
Congenital heart disease -- Periodicals
616.1204305 - Journal URLs:
- https://www.techscience.com/journal/chd ↗
http://firstsearch.oclc.org ↗
http://proxy.library.carleton.ca/login?url=http://www3.interscience.wiley.com/cgi-bin/issn?DESCRIPTOR=PRINTISSN&VALUE=1747-079X ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/chd ↗
http://www.blackwell-synergy.com/toc/chd/1/3;jsessionid=bBP_cvinxU9dsOWrNX ↗ - DOI:
- 10.1111/chd.12677 ↗
- Languages:
- English
- ISSNs:
- 1747-079X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3410.683800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9280.xml