54 Development of a model for predicting radiological risks in interventional cardiology. (December 2018)
- Record Type:
- Journal Article
- Title:
- 54 Development of a model for predicting radiological risks in interventional cardiology. (December 2018)
- Main Title:
- 54 Development of a model for predicting radiological risks in interventional cardiology
- Authors:
- Guérin, L.
Carpentier, S.
Leroy, F.
Maaloul, F. - Abstract:
- Abstract : Introduction: The aim of the study is to estimate, before intervention, the radiation dose that will be delivered to the patient during a recanalization of Chronic Total Occlusion (CTO). Relevant clinical indicators should be selected to predict, at best, the risk of deterministic effects and improve patient care. Methods: 103 CTO procedures were performed in a department of interventional cardiology with a Siemens Artis Zee C-arm giving Air Kerma. The peak skin dose was measured for each intervention, using radiochromic films. Patient parameters, such as gender, age weight and height were recorded. The complexity index (J-CTO score) which is specific to each intervention, was determined by the cardiologist. A correlation study has clarified the impact of these indicators on the dose. A predictive model of the dose to the patient was found. Results: Of the 103 patients studied, 5 were excluded from the study for clinical reasons, 2 others because radiochromic films were outside of the exposure field. Finally, 96 2D dose maps were used for the study. The factors showing the highest correlation with the peak skin dose are patient diameter and J-CTO score. The prediction model is therefore based on these two parameters. The comparison between the predicted skin dose and measured skin dose showed an average difference of 0.85 ± 0.55 Gy for doses less than 6 Gy. The average difference between Air-Kerma and peak skin dose is about 1.66 Gy ± 1.16 Gy. Conclusions: AnAbstract : Introduction: The aim of the study is to estimate, before intervention, the radiation dose that will be delivered to the patient during a recanalization of Chronic Total Occlusion (CTO). Relevant clinical indicators should be selected to predict, at best, the risk of deterministic effects and improve patient care. Methods: 103 CTO procedures were performed in a department of interventional cardiology with a Siemens Artis Zee C-arm giving Air Kerma. The peak skin dose was measured for each intervention, using radiochromic films. Patient parameters, such as gender, age weight and height were recorded. The complexity index (J-CTO score) which is specific to each intervention, was determined by the cardiologist. A correlation study has clarified the impact of these indicators on the dose. A predictive model of the dose to the patient was found. Results: Of the 103 patients studied, 5 were excluded from the study for clinical reasons, 2 others because radiochromic films were outside of the exposure field. Finally, 96 2D dose maps were used for the study. The factors showing the highest correlation with the peak skin dose are patient diameter and J-CTO score. The prediction model is therefore based on these two parameters. The comparison between the predicted skin dose and measured skin dose showed an average difference of 0.85 ± 0.55 Gy for doses less than 6 Gy. The average difference between Air-Kerma and peak skin dose is about 1.66 Gy ± 1.16 Gy. Conclusions: An initial estimate of the skin dose to the patient is given prior to the start of the intervention. This indication helps the cardiologist to work effectively and safely. This predicted dose is more accurate than the estimate provided by the air-kerma. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 1
- Issue Display:
- Volume 56, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2018-0056-0001-0000
- Page Start:
- 30
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.067 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9276.xml