1 Endorectal balloon for prostate SBRT: Influence on internal pudendal arteries dose sparing?. (December 2018)
- Record Type:
- Journal Article
- Title:
- 1 Endorectal balloon for prostate SBRT: Influence on internal pudendal arteries dose sparing?. (December 2018)
- Main Title:
- 1 Endorectal balloon for prostate SBRT: Influence on internal pudendal arteries dose sparing?
- Authors:
- Jaccard, M.
Lamanna, G.
Dubouloz, A.
Rouzaud, M.
Miralbell, R.
Zilli, T. - Abstract:
- Abstract : Introduction: One of the most common side effects from radiotherapy treatment of localized prostate cancer remains erectile dysfunction. Vessel-sparing radiotherapy has shown promising results on preserving erectile function when compared to historical series. In this dosimetric study, we aim to evaluate the influence of an endorectal balloon (ERB) on the dose sparing of internal pudendal arteries (IPA) in treatment planning of prostate stereotactic RT (SBRT). Methods: Twelve localized prostate cancer patients, simulated with and without ERB, were planned to receive 36.25 Gy (7.25Gyx5) to the planning treatment volume (PTV). IPA were delineated on each scanners using registration with MRI. Plans with and without ERB were optimized using Rapidplan™ (Varian), a knowledge based software, with standard sparing of regionally involved organs at risk (rectal and bladder wall, and femoral heads) and no dose constraints on IPA. A total of 24 volumetric arc therapy plans were optimized using a 10MV FFF beam with 2 full arcs. SBRT doses to IPA ( D 2 % and D mean ) were compared between groups using non-parametric tests. Results: The IPA volumes were similar in the two CT datasets, with a median volume of 4.75 cc (range, 3.8–7.2) vs. 4.95 cc (range, 3.8–7, p = 0.721) in patients with and without ERB, respectively. The median mean IPA dose was significantly lower using ERB (10.5 vs. 12.8 Gy, p = 0.023). Median IPA D 2 % was also lower with ERB (17.6 vs. 20.8 Gy without ERB),Abstract : Introduction: One of the most common side effects from radiotherapy treatment of localized prostate cancer remains erectile dysfunction. Vessel-sparing radiotherapy has shown promising results on preserving erectile function when compared to historical series. In this dosimetric study, we aim to evaluate the influence of an endorectal balloon (ERB) on the dose sparing of internal pudendal arteries (IPA) in treatment planning of prostate stereotactic RT (SBRT). Methods: Twelve localized prostate cancer patients, simulated with and without ERB, were planned to receive 36.25 Gy (7.25Gyx5) to the planning treatment volume (PTV). IPA were delineated on each scanners using registration with MRI. Plans with and without ERB were optimized using Rapidplan™ (Varian), a knowledge based software, with standard sparing of regionally involved organs at risk (rectal and bladder wall, and femoral heads) and no dose constraints on IPA. A total of 24 volumetric arc therapy plans were optimized using a 10MV FFF beam with 2 full arcs. SBRT doses to IPA ( D 2 % and D mean ) were compared between groups using non-parametric tests. Results: The IPA volumes were similar in the two CT datasets, with a median volume of 4.75 cc (range, 3.8–7.2) vs. 4.95 cc (range, 3.8–7, p = 0.721) in patients with and without ERB, respectively. The median mean IPA dose was significantly lower using ERB (10.5 vs. 12.8 Gy, p = 0.023). Median IPA D 2 % was also lower with ERB (17.6 vs. 20.8 Gy without ERB), but the difference was not significant. No clinically significant differences in target coverage, rectal, and bladder walls doses were observed between the two groups. Conclusions: The use of ERB for prostate SBRT showed a significant sparing of IPA compared to plans generated with an empty rectum. As no specific dose constraints are yet available for vessel-sparing SBRT, optimal reduction of IPA doses should be attempted for maximal EF preservation. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 1
- Issue Display:
- Volume 56, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2018-0056-0001-0000
- Page Start:
- 40
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.083 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9276.xml