9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy. (December 2018)
- Record Type:
- Journal Article
- Title:
- 9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy. (December 2018)
- Main Title:
- 9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy
- Authors:
- Colnot, J.
Garnier, G.
Zefkili, S.
Gschwind, R.
Huet, C. - Abstract:
- Abstract : Introduction: Recently, cancer treatment improvement enabled an increase in patients' survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks[1] . Moreover, the longer patients' life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy techniques. Those dosimetric data are prerequisites for risk evaluation. Methods: The tool developed on Matlab is based on 3D dose reconstruction from 2D dose measurements performed using radiochromic films placed between phantom slices. The tool proceeds to fine spatial films/TPS dose matching near the target volume and then reconstructs the 3D dose distribution by interpolation of films dose measurements. Finally, interesting dosimetric data such as dose-volume histograms are evaluated. A first validation of the tool has been performed with the EasyCube phantom irradiated with two films spaced 2 cm apart and placed in target volume. After scanning and contouring, the phantom was irradiated according to a treatment planning with the films in place. Films were analyzed using aAbstract : Introduction: Recently, cancer treatment improvement enabled an increase in patients' survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks[1] . Moreover, the longer patients' life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy techniques. Those dosimetric data are prerequisites for risk evaluation. Methods: The tool developed on Matlab is based on 3D dose reconstruction from 2D dose measurements performed using radiochromic films placed between phantom slices. The tool proceeds to fine spatial films/TPS dose matching near the target volume and then reconstructs the 3D dose distribution by interpolation of films dose measurements. Finally, interesting dosimetric data such as dose-volume histograms are evaluated. A first validation of the tool has been performed with the EasyCube phantom irradiated with two films spaced 2 cm apart and placed in target volume. After scanning and contouring, the phantom was irradiated according to a treatment planning with the films in place. Films were analyzed using a rigorous protocol[2] developed by our group. Results: Both 2D and volumetric comparisons between measured and planned doses gave good results. Indeed, 89.2% of points pass the 3 mm/3% gamma test when comparing interpolated dose distribution and planned dose on the middle slice. Likewise, a 2.6% discrepancy on mean PTV doses has been observed between the two distributions and the mean shift between the 0.4 Gy isodoses is of 0.10 mm on the middle slice. Conclusions: The original tool developed in this work enables an experimental evaluation of normal tissue doses: essential dosimetric data for risk evaluation models. The preliminary feasibility study shows promising results. Validation and optimization on a more important volume is currently ongoing. Finally, validation using 3D gel dosimetry is considered. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 1
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 1
- Issue Display:
- Volume 56, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2018-0056-0001-0000
- Page Start:
- 44
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.091 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9276.xml