SMART coils for intracranial aneurysm embolization: Follow-up outcomes. (January 2019)
- Record Type:
- Journal Article
- Title:
- SMART coils for intracranial aneurysm embolization: Follow-up outcomes. (January 2019)
- Main Title:
- SMART coils for intracranial aneurysm embolization: Follow-up outcomes
- Authors:
- Sokolowski, Jennifer D.
Ilyas, Adeel
Buell, Thomas J.
Taylor, Davis G.
Chen, Ching-Jen
Ding, Dale
Raper, Daniel M.S.
Liu, Kenneth C. - Abstract:
- Highlights: SMART coils are designed to enhance deliverability. They are safe and efficacious for treatment of appropriately selected aneurysms. Rates of occlusion achieved coils are comparable to other coil technologies. Residual aneurysms often progress to complete or near-complete occlusion. Abstract: The SMART coil (Penumbra Inc., Alameda, CA, USA) is a new microcoil designed to enhance deliverability. Although prior studies have described its perioperative safety and efficacy, the follow-up outcomes after embolization of intracranial aneurysms using SMART coils have not been reported. Therefore, the aim of this retrospective cohort study is to assess the angiographic outcomes at interim follow-up after aneurysm embolization with SMART coils. We reviewed data from consecutive patients with intracranial aneurysms who underwent endovascular treatment using SMART coils between June 2016 and August 2017. Baseline data and follow-up angiographic outcomes using the modified Raymond-Roy classification (MRRC) were recorded. The study cohort comprised 33 patients with 34 aneurysms who underwent SMART coil embolization and had sufficient follow-up data. The mean age was 57 years, and 82% were female. The mean aneurysm maximum diameter and neck width were 6.1 ± 2.2 mm and 3.2 ± 1.2 mm, respectively, and 14.7% of aneurysms were ruptured. The overall complication rate was 12%. Initial mean coil packing density was 26%, and the initial MRRC was I, II, IIIa, and IIIb in 24%, 26%, 35%,Highlights: SMART coils are designed to enhance deliverability. They are safe and efficacious for treatment of appropriately selected aneurysms. Rates of occlusion achieved coils are comparable to other coil technologies. Residual aneurysms often progress to complete or near-complete occlusion. Abstract: The SMART coil (Penumbra Inc., Alameda, CA, USA) is a new microcoil designed to enhance deliverability. Although prior studies have described its perioperative safety and efficacy, the follow-up outcomes after embolization of intracranial aneurysms using SMART coils have not been reported. Therefore, the aim of this retrospective cohort study is to assess the angiographic outcomes at interim follow-up after aneurysm embolization with SMART coils. We reviewed data from consecutive patients with intracranial aneurysms who underwent endovascular treatment using SMART coils between June 2016 and August 2017. Baseline data and follow-up angiographic outcomes using the modified Raymond-Roy classification (MRRC) were recorded. The study cohort comprised 33 patients with 34 aneurysms who underwent SMART coil embolization and had sufficient follow-up data. The mean age was 57 years, and 82% were female. The mean aneurysm maximum diameter and neck width were 6.1 ± 2.2 mm and 3.2 ± 1.2 mm, respectively, and 14.7% of aneurysms were ruptured. The overall complication rate was 12%. Initial mean coil packing density was 26%, and the initial MRRC was I, II, IIIa, and IIIb in 24%, 26%, 35%, and 15%, respectively. At last follow-up (mean duration 7.7 ± 3.2 months), the MRRC was I, II, IIIa, and IIIb in 62%, 26%, 3%, and 9%, respectively. The retreatment rate was 14.7%. The SMART coil is efficacious for the treatment of appropriately selected aneurysms, with an acceptable risk profile. The majority of residual aneurysms after the initial embolization procedure will progress to complete or near-complete occlusion at interim follow-up. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 59(2019)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 59(2019)
- Issue Display:
- Volume 59, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 2019
- Issue Sort Value:
- 2019-0059-2019-0000
- Page Start:
- 93
- Page End:
- 97
- Publication Date:
- 2019-01
- Subjects:
- Aneurysm -- Endovascular -- Coil embolization -- Technology
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2018.10.132 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9270.xml