Effect of pneumatic tube transport on T lymphocyte subsets analysis. Issue 6 (16th July 2015)
- Record Type:
- Journal Article
- Title:
- Effect of pneumatic tube transport on T lymphocyte subsets analysis. Issue 6 (16th July 2015)
- Main Title:
- Effect of pneumatic tube transport on T lymphocyte subsets analysis
- Authors:
- Gossez, Morgane
Poitevin‐Later, Francoise
Demaret, Julie
Jallades, Laurent
Venet, Fabienne
Malcus, Christophe
Monneret, Guillaume - Abstract:
- Abstract : Background: Pneumatic tube system (PTS) for transportation of blood specimens may present with advantages for hospital organization as it provides faster tube transfer from medical wards to routine labs. These characteristics are expected to result in faster sample processing and decreased turnaround time, therefore benefiting the patient particularly in emergency units. However, PTS could affect sample quality and therefore laboratory results. Within the context of routine lab certification, effects of PTS on routine cellular immunology analyses, especially on determination of T lymphocyte subpopulations, need to be evaluated. Methods: Paired EDTA blood samples were collected from 30 healthy donors. For each pair, one sample was hand‐delivered by a courier while the other was transported through a PTS of 2.4 km long (1.6 miles) with two 90‐degree turns and one‐U turn generating a speed of 5 m/s with a maximal acceleration of 2 g‐force. The percentages of CD3+ cells, CD4+ and CD8+ T‐cells and their absolute counts were assessed by flow cytometry. Results: For every parameter, results measured by flow cytometry were not significantly different after transport by PTS or hand‐delivery. Results comparison revealed an excellent linear correlation between both delivery methods (R ranged from 0.969 to 0.982; P < 0.01). Bland‐Altman plots also showed good agreement, indicating that results were not influenced by the transport method. Conclusions: Our results suggestAbstract : Background: Pneumatic tube system (PTS) for transportation of blood specimens may present with advantages for hospital organization as it provides faster tube transfer from medical wards to routine labs. These characteristics are expected to result in faster sample processing and decreased turnaround time, therefore benefiting the patient particularly in emergency units. However, PTS could affect sample quality and therefore laboratory results. Within the context of routine lab certification, effects of PTS on routine cellular immunology analyses, especially on determination of T lymphocyte subpopulations, need to be evaluated. Methods: Paired EDTA blood samples were collected from 30 healthy donors. For each pair, one sample was hand‐delivered by a courier while the other was transported through a PTS of 2.4 km long (1.6 miles) with two 90‐degree turns and one‐U turn generating a speed of 5 m/s with a maximal acceleration of 2 g‐force. The percentages of CD3+ cells, CD4+ and CD8+ T‐cells and their absolute counts were assessed by flow cytometry. Results: For every parameter, results measured by flow cytometry were not significantly different after transport by PTS or hand‐delivery. Results comparison revealed an excellent linear correlation between both delivery methods (R ranged from 0.969 to 0.982; P < 0.01). Bland‐Altman plots also showed good agreement, indicating that results were not influenced by the transport method. Conclusions: Our results suggest that, pending validation using clinical samples, PTS does not present with pre‐analytical drawbacks and is thus a reliable system for blood samples transportation when performing T cell subset phenotyping. © 2015 International Clinical Cytometry Society … (more)
- Is Part Of:
- Cytometry. Volume 88:Issue 6(2015)
- Journal:
- Cytometry
- Issue:
- Volume 88:Issue 6(2015)
- Issue Display:
- Volume 88, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 88
- Issue:
- 6
- Issue Sort Value:
- 2015-0088-0006-0000
- Page Start:
- 371
- Page End:
- 374
- Publication Date:
- 2015-07-16
- Subjects:
- certification -- flow cytometry -- pneumatic tube transport -- T lymphocytes
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21231 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9202.xml