Syndecan-1 in mechanosensing of nanotopological cues in engineered materials. (February 2018)
- Record Type:
- Journal Article
- Title:
- Syndecan-1 in mechanosensing of nanotopological cues in engineered materials. (February 2018)
- Main Title:
- Syndecan-1 in mechanosensing of nanotopological cues in engineered materials
- Authors:
- Le, Victoria
Lee, Jason
Chaterji, Somali
Spencer, Adrianne
Liu, Yen-Liang
Kim, Peter
Yeh, Hsin-Chih
Kim, Deok-Ho
Baker, Aaron B. - Abstract:
- Abstract: The cells of the vascular system are highly sensitive to biophysical cues from their local cellular microenvironment. To engineer improved materials for vascular devices and delivery of cell therapies, a key challenge is to understand the mechanisms that cells use to sense biophysical cues from their environment. Syndecans are heparan sulfate proteoglycans (HSPGs) that consist of a protein core modified with heparan sulfate glycosaminoglycan chains. Due to their presence on the cell surface and their interaction with cytoskeletal and focal adhesion associated molecules, cell surface proteoglycans are well poised to serve as mechanosensors of the cellular microenvironment. Nanotopological cues have become recognized as major regulators of cell growth, migration and phenotype. We hypothesized that syndecan-1 could serve as a mechanosensor for nanotopological cues and can mediate the responsiveness of vascular smooth muscle cells to nanoengineered materials. We created engineered substrates made of polyurethane acrylate with nanogrooves using ultraviolet-assisted capillary force lithography. We cultured vascular smooth muscle cells with knockout of syndecan-1 on engineered substrates with varying compliance and nanotopology. We found that knockout of syndecan-1 reduced alignment of vascular smooth muscle cells to the nanogrooves under inflammatory treatments. In addition, we found that loss of syndecan-1 increased nuclear localization of Yap/Taz and phospho-Smad2/3 inAbstract: The cells of the vascular system are highly sensitive to biophysical cues from their local cellular microenvironment. To engineer improved materials for vascular devices and delivery of cell therapies, a key challenge is to understand the mechanisms that cells use to sense biophysical cues from their environment. Syndecans are heparan sulfate proteoglycans (HSPGs) that consist of a protein core modified with heparan sulfate glycosaminoglycan chains. Due to their presence on the cell surface and their interaction with cytoskeletal and focal adhesion associated molecules, cell surface proteoglycans are well poised to serve as mechanosensors of the cellular microenvironment. Nanotopological cues have become recognized as major regulators of cell growth, migration and phenotype. We hypothesized that syndecan-1 could serve as a mechanosensor for nanotopological cues and can mediate the responsiveness of vascular smooth muscle cells to nanoengineered materials. We created engineered substrates made of polyurethane acrylate with nanogrooves using ultraviolet-assisted capillary force lithography. We cultured vascular smooth muscle cells with knockout of syndecan-1 on engineered substrates with varying compliance and nanotopology. We found that knockout of syndecan-1 reduced alignment of vascular smooth muscle cells to the nanogrooves under inflammatory treatments. In addition, we found that loss of syndecan-1 increased nuclear localization of Yap/Taz and phospho-Smad2/3 in response to nanogrooves. Syndecan-1 knockout vascular smooth muscle cells also had elevated levels of Rho-associated protein kinase-1 (Rock1), leading to increased cell stiffness and an enhanced contractile state in the cells. Together, our findings support that syndecan-1 knockout leads to alterations in mechanosensing of nanotopographical cues through alterations of in rho-associated signaling pathways, cell mechanics and mediators of the Hippo and TGF-β signaling pathways. … (more)
- Is Part Of:
- Biomaterials. Volume 155(2018)
- Journal:
- Biomaterials
- Issue:
- Volume 155(2018)
- Issue Display:
- Volume 155, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 155
- Issue:
- 2018
- Issue Sort Value:
- 2018-0155-2018-0000
- Page Start:
- 13
- Page End:
- 24
- Publication Date:
- 2018-02
- Subjects:
- Syndecan-1 -- Mechanosensing -- Vascular smooth muscle cells -- Nanotopology -- Nanogrooves -- Capillary force lithography -- Hippo signaling pathway -- Rho-associated protein kinase-1 (Rock1) -- TGF-β
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2017.11.007 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9200.xml