Evaluation of peri‐implant buccal bone by computed tomography: an experimental study. Issue 8 (14th July 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of peri‐implant buccal bone by computed tomography: an experimental study. Issue 8 (14th July 2015)
- Main Title:
- Evaluation of peri‐implant buccal bone by computed tomography: an experimental study
- Authors:
- González‐Martín, Oscar
Oteo, Carlos
Ortega, Ricardo
Alandez, Javier
Sanz, Mariano
Veltri, Mario - Abstract:
- Abstract: Objectives: To evaluate the accuracy of measuring peri‐implant buccal bone when using three different computed tomography devices. Materials and methods: Sixty tissue‐level or bone‐level dental implants were placed in bovine ribs with either buccal bone full coverage, dehiscence or fenestration. For each site, the distance from the bone defect to the implant neck and the buccal bone thickness 1 mm apical to the crest were measured using a calliper. Subsequently, all sites were scanned in a reproducible position using a multi‐slice computed tomography (CT) (Brightspeed, voxel size 0.625 mm) and two cone‐beam computed tomography devices (i‐CAT NG, voxel size 0.3 mm and Newtom VGi, voxel size 0.2 mm). Bone thickness was measured on images from the three systems similar to direct measurements and differences were evaluated. Factors that could influence the buccal bone identification were assessed by multiple binary logistic regression. Results: Buccal bone ranged from 0.1 mm to 2.75 mm in thickness and was not visible in 68%, 63% and 60% of cases when using CT, i‐CAT and Newtom, respectively. For each mm of bone thickness increment, the odds of radiographic identification increased by 30.6 ( P < 0.001). Bone defects negatively affected radiographic visibility ( P < 0.05). All devices underestimated bone dimensions although differences among them were not significant. Conclusions: Within these experimental conditions, the investigated devices have equivalent lowAbstract: Objectives: To evaluate the accuracy of measuring peri‐implant buccal bone when using three different computed tomography devices. Materials and methods: Sixty tissue‐level or bone‐level dental implants were placed in bovine ribs with either buccal bone full coverage, dehiscence or fenestration. For each site, the distance from the bone defect to the implant neck and the buccal bone thickness 1 mm apical to the crest were measured using a calliper. Subsequently, all sites were scanned in a reproducible position using a multi‐slice computed tomography (CT) (Brightspeed, voxel size 0.625 mm) and two cone‐beam computed tomography devices (i‐CAT NG, voxel size 0.3 mm and Newtom VGi, voxel size 0.2 mm). Bone thickness was measured on images from the three systems similar to direct measurements and differences were evaluated. Factors that could influence the buccal bone identification were assessed by multiple binary logistic regression. Results: Buccal bone ranged from 0.1 mm to 2.75 mm in thickness and was not visible in 68%, 63% and 60% of cases when using CT, i‐CAT and Newtom, respectively. For each mm of bone thickness increment, the odds of radiographic identification increased by 30.6 ( P < 0.001). Bone defects negatively affected radiographic visibility ( P < 0.05). All devices underestimated bone dimensions although differences among them were not significant. Conclusions: Within these experimental conditions, the investigated devices have equivalent low accuracy in diagnosing peri‐implant buccal bone. Accuracy was significantly influenced by buccal bone thickness, especially if <1 mm, and in presence of peri‐implant marginal defects. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 27:Issue 8(2016)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 27:Issue 8(2016)
- Issue Display:
- Volume 27, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 8
- Issue Sort Value:
- 2016-0027-0008-0000
- Page Start:
- 950
- Page End:
- 955
- Publication Date:
- 2015-07-14
- Subjects:
- cone‐beam CT -- cortical bone -- dental implant
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12663 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9179.xml