Computed Tomography Images of the Scapula Taken With Reduced Dose Can Yield Segmented Models of Sufficient Accuracy: A Pilot Study. Issue 3 (May 2018)
- Record Type:
- Journal Article
- Title:
- Computed Tomography Images of the Scapula Taken With Reduced Dose Can Yield Segmented Models of Sufficient Accuracy: A Pilot Study. Issue 3 (May 2018)
- Main Title:
- Computed Tomography Images of the Scapula Taken With Reduced Dose Can Yield Segmented Models of Sufficient Accuracy
- Authors:
- Herteleer, Michiel
Vancleef, Sanne
Nijs, Stefaan
Vander Sloten, Jos - Abstract:
- Abstract : Objective: The aim of the study was to investigate the influence of tube current reduction on the segmentation accuracy of the scapula. Methods: A human cadaver was computed tomography scanned multiple times while reducing tube current amperage. The images were segmented using 2 different segmentation methods (N = 28). Subsequently the scapula was dissected and all soft tissues were removed. An optical laser scan of the dissected scapula was aligned and compared with the segmented meshes of the different computed tomography scans. Results: The mesh accuracy remained fairly constant with diminishing tube currents. All segmented meshes had a larger volume than the reference mesh (n = 27). The mean 3-dimensional deviation varied between 1.17 mm (max) and −0.759 mm (min) and the total mean (SD) 3-dimensional deviation was −0.45 (0.38) mm. Radiation dosages were reduced from 7.1 to 0.3 mSv. Conclusions: Computed tomography tube current can be largely reduced without losing the surface segmentation accuracy of segmented scapula meshes.
- Is Part Of:
- Journal of computer assisted tomography. Volume 42:Issue 3(2018)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 42:Issue 3(2018)
- Issue Display:
- Volume 42, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 3
- Issue Sort Value:
- 2018-0042-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-05
- Subjects:
- scapula -- segmentation -- low-dose CT -- 3D
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000706 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9177.xml