A comparison of commercially available compression feedback devices in novice and experienced healthcare practitioners: A prospective randomized simulation study. Issue 3 (22nd November 2018)
- Record Type:
- Journal Article
- Title:
- A comparison of commercially available compression feedback devices in novice and experienced healthcare practitioners: A prospective randomized simulation study. Issue 3 (22nd November 2018)
- Main Title:
- A comparison of commercially available compression feedback devices in novice and experienced healthcare practitioners: A prospective randomized simulation study
- Authors:
- Davis, Terri L.
Hoffman, Adam
Vahedian‐Azimi, Amir
Brewer, Kori L.
Miller, Andrew C. - Abstract:
- Abstract: Background: Guidelines note the importance of chest compression components including rate, depth, no‐flow time and chest recoil. Audio‐visual feedback (AVF) technologies are included in the American Heart Association's training videos and loosely recommended by the 2015 guidelines. Objective: To compare the effectiveness of 3 compression AVF devices compared to standard compressions. Methods: Prospective simulation study of 118 subjects randomized into 4 groups: TrueCPR™, Pocket CPR™, CPR RsQ Assist® and Control. The SimMan® 3G simulator recorded compression total, rate, depth, recoil, no‐flow time and flow fraction during 6 min of continuous compressions. Results: Compression number and rate were similar, and depth was poor across all groups, but TrueCPR™ and PocketCPR™ demonstrated statically (not clinically) significant improvements compared to control ( p = 0.024) and CPR RsQ Assist® groups ( p < 0.001). PocketCPR™ had the greatest % compressions with sufficient depth, while TrueCPR™ had the greatest % with adequate rate. Controls outperformed all devices in no‐flow time ( p < 0.001) and flow fraction ( p < 0.001). Full recoil was not improved by device use ( p = 0.31). Conclusion: In this simulation study, PocketCPR™ was the highest performing AVF device. AVF use improved mean compression depth and per cent compressions with adequate rate or depth. Devices underperformed for recoil, no‐flow time and flow fraction. Metronome components most benefitedAbstract: Background: Guidelines note the importance of chest compression components including rate, depth, no‐flow time and chest recoil. Audio‐visual feedback (AVF) technologies are included in the American Heart Association's training videos and loosely recommended by the 2015 guidelines. Objective: To compare the effectiveness of 3 compression AVF devices compared to standard compressions. Methods: Prospective simulation study of 118 subjects randomized into 4 groups: TrueCPR™, Pocket CPR™, CPR RsQ Assist® and Control. The SimMan® 3G simulator recorded compression total, rate, depth, recoil, no‐flow time and flow fraction during 6 min of continuous compressions. Results: Compression number and rate were similar, and depth was poor across all groups, but TrueCPR™ and PocketCPR™ demonstrated statically (not clinically) significant improvements compared to control ( p = 0.024) and CPR RsQ Assist® groups ( p < 0.001). PocketCPR™ had the greatest % compressions with sufficient depth, while TrueCPR™ had the greatest % with adequate rate. Controls outperformed all devices in no‐flow time ( p < 0.001) and flow fraction ( p < 0.001). Full recoil was not improved by device use ( p = 0.31). Conclusion: In this simulation study, PocketCPR™ was the highest performing AVF device. AVF use improved mean compression depth and per cent compressions with adequate rate or depth. Devices underperformed for recoil, no‐flow time and flow fraction. Metronome components most benefited novice providers. Further study is warranted before recommending AVF use in routine clinical practice. … (more)
- Is Part Of:
- Medical devices & sensors. Volume 1:Issue 3(2018)
- Journal:
- Medical devices & sensors
- Issue:
- Volume 1:Issue 3(2018)
- Issue Display:
- Volume 1, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 1
- Issue:
- 3
- Issue Sort Value:
- 2018-0001-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-11-22
- Subjects:
- cardiopulmonary resuscitation -- chest compression -- medical device -- simulation -- technology
Medical instruments and apparatus -- Periodicals
Biomedical engineering -- Periodicals
Electronic journals
Periodicals
610.28 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/2573802x ↗
- DOI:
- 10.1002/mds3.10020 ↗
- Languages:
- English
- ISSNs:
- 2573-802X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.055436
British Library HMNTS - ELD Digital store - Ingest File:
- 9166.xml