Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs. (November 2015)
- Record Type:
- Journal Article
- Title:
- Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs. (November 2015)
- Main Title:
- Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs
- Authors:
- Pathirana, Sameera Wijesiri
Uy, Brian
Mirza, Olivia
Zhu, Xinqun - Abstract:
- Abstract: This paper considers the flexural behaviour of steel-concrete composite beams retrofitted with two types of bolted connectors and welded stud connectors. Three composite beams, one from each connector type, and four non-composite beams were cast together. Three of the non-composite beams were retrofitted using the three connector types respectively. The connectors were installed through holes cored in the concrete slabs of the beams. The holes were backfilled using structural grout. The beams were then tested under static flexural loading. The load-slip behaviour of these connectors under normal and retrofitted conditions was investigated using push-tests. The flexural behaviour of the retrofitted beams was compared with that of the normal composite beams and non-composite beams. The ultimate loads of the test specimens were compared with the design ultimate loads of these beams calculated using Rigid Plastic Analysis (RPA). The vertical deflection of the beams under serviceable load regimes was also compared. The beam experiments were simulated using Finite Element (FE) models developed with ABAQUS. Material models with damage parameters were specified for the concrete and grout used in the test specimens using the Concrete Damage Plasticity (CDP) option. The effects of the concrete and grout strength, grout-hole size and shear connection ratio on the flexural behaviour of retrofitted beams were investigated by carrying out a parametric analysis. The resultsAbstract: This paper considers the flexural behaviour of steel-concrete composite beams retrofitted with two types of bolted connectors and welded stud connectors. Three composite beams, one from each connector type, and four non-composite beams were cast together. Three of the non-composite beams were retrofitted using the three connector types respectively. The connectors were installed through holes cored in the concrete slabs of the beams. The holes were backfilled using structural grout. The beams were then tested under static flexural loading. The load-slip behaviour of these connectors under normal and retrofitted conditions was investigated using push-tests. The flexural behaviour of the retrofitted beams was compared with that of the normal composite beams and non-composite beams. The ultimate loads of the test specimens were compared with the design ultimate loads of these beams calculated using Rigid Plastic Analysis (RPA). The vertical deflection of the beams under serviceable load regimes was also compared. The beam experiments were simulated using Finite Element (FE) models developed with ABAQUS. Material models with damage parameters were specified for the concrete and grout used in the test specimens using the Concrete Damage Plasticity (CDP) option. The effects of the concrete and grout strength, grout-hole size and shear connection ratio on the flexural behaviour of retrofitted beams were investigated by carrying out a parametric analysis. The results obtained from full-scale beam and push-test experiments and also the analytical results from RPA and FE analyses are presented and discussed in detail in this paper. Highlights: Feasibility of utilising blind bolt connectors in retrofitting of steel-concrete composite beams was investigated. Bolted connectors demonstrated much higher shear capacity than the welded stud connectors in both the normal and retrofitted conditions. The existing non-composite beams were feasibly retrofitted utilising the bolts. The strength of a non-composite beam was increased by approximately 40% by using the BB2 connectors. The capacity of the retrofitted beams is increased with the concrete strength and it is not considerably influenced by the grout strength or the grout-hole size. … (more)
- Is Part Of:
- Journal of constructional steel research. Volume 114(2015:Nov.)
- Journal:
- Journal of constructional steel research
- Issue:
- Volume 114(2015:Nov.)
- Issue Display:
- Volume 114 (2015)
- Year:
- 2015
- Volume:
- 114
- Issue Sort Value:
- 2015-0114-0000-0000
- Page Start:
- 417
- Page End:
- 430
- Publication Date:
- 2015-11
- Subjects:
- Bolted connectors -- Composite beams -- Damage parameters -- Finite element modeling -- Grout -- Push-tests -- Rigid plastic analysis -- Retrofitting -- Shear connectors
Steel, Structural -- Periodicals
Building, Iron and steel -- Periodicals
Acier de construction -- Périodiques
Construction métallique -- Périodiques
624.1821 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0143974X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcsr.2015.09.006 ↗
- Languages:
- English
- ISSNs:
- 0143-974X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.193000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9162.xml