Performance evaluation of the microINR® point‐of‐care INR‐testing system. (6th October 2017)
- Record Type:
- Journal Article
- Title:
- Performance evaluation of the microINR® point‐of‐care INR‐testing system. (6th October 2017)
- Main Title:
- Performance evaluation of the microINR® point‐of‐care INR‐testing system
- Authors:
- Joubert, J.
van Zyl, M.C.
Raubenheimer, J. - Abstract:
- Abstract: Introduction: Point‐of‐care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Methods: Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS‐2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger‐prick INRs. Triplicate finger‐prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Results: Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 ( P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument ( P = .93) or test chip ( P = .81) variability was found, and the error rate was low (2.8%). Conclusion: The microINR ® instrument is accurate and precise for monitoring warfarin therapy.
- Is Part Of:
- International journal of laboratory hematology. Volume 40:Number 2(2018:Apr.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 40:Number 2(2018:Apr.)
- Issue Display:
- Volume 40, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2018-0040-0002-0000
- Page Start:
- 115
- Page End:
- 122
- Publication Date:
- 2017-10-06
- Subjects:
- international normalised ratio -- micro international normalised ratio® -- oral anticoagulant therapy -- performance evaluation -- point‐of‐care
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12749 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9154.xml