Palareti, G. - Abstract:
- Abstract: Introduction: Several specific assays are commercially available to determine dabigatran anticoagulant activity. Aims of this multicenter and multiplatform study were to compare five methods for dabigatran measurement and investigate their performances in the low concentration range. Methods: Dabigatran levels were analyzed in 295 plasma samples from patients enrolled in the START‐Laboratory Register by the following methods using dedicated calibrators and controls: STA‐ECA II (Diagnostica Stago), standard and low range Hemoclot Thrombin Inhibitors (Hyphen BioMed), Direct Thrombin Inhibitor Assay (Instrumentation Laboratory), Direct Thrombin Inhibitor Assay (Siemens), Technoclot DTI (Technoclone). Results: Methods showed variable agreement with the Hemoclot Thrombin Inhibitors assay used as reference test, with modest under‐ or overestimations (Bland‐Altman bias from −17.3 to 4.0 ng/mL). Limits of detection and quantification varied depending on the assay (4‐52 and 7‐82 ng/mL, respectively). Between‐run precision and accuracy were good for all methods for both quality control levels. Assay's repeatability assessed at very low dabigatran concentrations (from 10 to 60 ng/mL) was also acceptable, variability generally increased at lower drug levels. Conclusion: The five dabigatran‐specific assays evaluated in this study provided reliable assessment of dabigatran plasma levels, although showing different performances.
- Is Part Of:
- International journal of laboratory hematology. Volume 40:Number 2(2018:Apr.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 40:Number 2(2018:Apr.)
- Issue Display:
- Volume 40, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2018-0040-0002-0000
- Page Start:
- 229
- Page End:
- 236
- Publication Date:
- 2018-01-03
- Subjects:
- chromogenic assay -- clotting assay -- dabigatran -- direct thrombin inhibitor -- laboratory testing
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12772 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9154.xml