Development and validation of a hydrophilic interaction ultra‐high‐performance liquid chromatography–tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine. (24th October 2018)
- Record Type:
- Journal Article
- Title:
- Development and validation of a hydrophilic interaction ultra‐high‐performance liquid chromatography–tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine. (24th October 2018)
- Main Title:
- Development and validation of a hydrophilic interaction ultra‐high‐performance liquid chromatography–tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine
- Authors:
- Wen, Yongqing
Yuan, Xuemei
Qin, Feng
Zhao, Longshan
Xiong, Zhili - Other Names:
- Weng Naidong guestEditor.
Srinivas Nuggehally guestEditor. - Abstract:
- Abstract: Determination of amino acids in biofluids is a challenging task because of difficulties deriving from their high polarity and matrix interference. A simple, reliable and high‐throughput hydrophilic interaction UHPLC–MS/MS method was developed and validated for the rapid simultaneous determination of 19 free amino acids in rat plasma and urine samples in this paper. Hydrophilic method with a Waters Acquity UPLC BEH Amide column (100 × 2.1 mm, 1.7 μm) was used with a gradient mobile phase system of acetonitrile and water both containing 0.2% formic acid. The analysis was performed on a positive electrospray ionization mass spectrometer via multiple reaction monitoring. Samples of 10 μL plasma and 50 μL urine were spiked with three deuterated internal standards, pretreated with 250 μL acetonitrile for one‐step protein precipitation and a final dilution of urine samples. Good linearities ( r > 0.99) were obtained for all of the analytes with the lower limit of quantification from 0.1 to 1.2 μg/mL. The relative standard deviation of the intra‐day and inter‐day precisions were within 15.0% and the accuracy ranged from −12.8 to 12.7%. The hydrophilic interaction UHPLC–MS/MS method was rapid, accurate and high‐throughput and exhibited better chromatography behaviors than the regular RPLC methods. It was further successfully applied to detect 19 free amino acids in biological matrix.
- Is Part Of:
- Biomedical chromatography. Volume 33:Number 1(2019)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 33:Number 1(2019)
- Issue Display:
- Volume 33, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2019-0033-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-10-24
- Subjects:
- 19 free amino acids -- determination -- hydrophilic interaction ultra‐high‐performance liquid chromatography–tandem mass spectrometry -- rat plasma -- urine
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.4387 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9150.xml