Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance. (March 2019)
- Record Type:
- Journal Article
- Title:
- Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance. (March 2019)
- Main Title:
- Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance
- Authors:
- Jung, Ki Wook
Kharangate, Chirag R.
Lee, Hyoungsoon
Palko, James
Zhou, Feng
Asheghi, Mehdi
Dede, Ercan M.
Goodson, Kenneth E. - Abstract:
- Graphical abstract: Highlights: Thermal-fluidic performance of microchannels with a 3-D manifold was investigated. Heat fluxes were tested up to 250 W/cm 2 with varied flow rates up to 0.1 l/min. Numerical simulations are compared and agreed well with the experimental results. The simulation predicts that 850 W/cm 2 can be removed with flow rate of 0.1 l/min. Abstract: Single-phase thermal-fluidic performance of an embedded silicon microchannel cold-plate (25 parallel channels: 75 μm × 150 μm) with a 3-D liquid distribution manifold (6 inlets: 700 μm × 150 μm) and vapor extraction conduits, is investigated using water as working fluid. A 3D manifold is fabricated from silicon and bonded to a silicon microchannel substrate to form a monolithic microcooler (μ-cooler). A metal serpentine bridge (5 2 mm 2 of footprint) and multiple resistance temperature detectors (RTDs) are used for electrical Joule-heating and thermometry, respectively. The experimental results for maximum and average temperatures of the chip, pressure drop, thermal resistance (as low as 0.68 K/W), average heat transfer coefficient (∼30, 000–50, 000 W/m 2 K) for flow rates of 0.03, 0.06 and 0.1 l/min and heat fluxes of 60, 100 and 250 W/cm 2 are reported. The embedded microchannel-3D manifold μ-cooler device is capable of removing 250 W/cm 2 at a maximum temperature of 90 °C with less than 3 kPa pressure drop for a flow rate of 0.1 l/min. The results from conjugate thermal-fluidic numerical simulations agreeGraphical abstract: Highlights: Thermal-fluidic performance of microchannels with a 3-D manifold was investigated. Heat fluxes were tested up to 250 W/cm 2 with varied flow rates up to 0.1 l/min. Numerical simulations are compared and agreed well with the experimental results. The simulation predicts that 850 W/cm 2 can be removed with flow rate of 0.1 l/min. Abstract: Single-phase thermal-fluidic performance of an embedded silicon microchannel cold-plate (25 parallel channels: 75 μm × 150 μm) with a 3-D liquid distribution manifold (6 inlets: 700 μm × 150 μm) and vapor extraction conduits, is investigated using water as working fluid. A 3D manifold is fabricated from silicon and bonded to a silicon microchannel substrate to form a monolithic microcooler (μ-cooler). A metal serpentine bridge (5 2 mm 2 of footprint) and multiple resistance temperature detectors (RTDs) are used for electrical Joule-heating and thermometry, respectively. The experimental results for maximum and average temperatures of the chip, pressure drop, thermal resistance (as low as 0.68 K/W), average heat transfer coefficient (∼30, 000–50, 000 W/m 2 K) for flow rates of 0.03, 0.06 and 0.1 l/min and heat fluxes of 60, 100 and 250 W/cm 2 are reported. The embedded microchannel-3D manifold μ-cooler device is capable of removing 250 W/cm 2 at a maximum temperature of 90 °C with less than 3 kPa pressure drop for a flow rate of 0.1 l/min. The results from conjugate thermal-fluidic numerical simulations agree well with the experimental data over the wide range of heat fluxes and flow conditions. The numerical simulation results also hint at the possibility of removing up to ∼850 W/cm 2 using single-phase water at a maximum temperature of 166 °C at the same pressure drop and flow rate. This offers a very attractive strategy/option for cooling of high heat flux power electronics using single-phase water. … (more)
- Is Part Of:
- International journal of heat and mass transfer. Volume 130(2019)
- Journal:
- International journal of heat and mass transfer
- Issue:
- Volume 130(2019)
- Issue Display:
- Volume 130, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 130
- Issue:
- 2019
- Issue Sort Value:
- 2019-0130-2019-0000
- Page Start:
- 1108
- Page End:
- 1119
- Publication Date:
- 2019-03
- Subjects:
- Embedded microchannel -- 3D manifold -- Monolithic microcooler -- Conjugate thermal-fluidic numerical simulations -- Single-phase water cooling experiments
Heat -- Transmission -- Periodicals
Mass transfer -- Periodicals
Chaleur -- Transmission -- Périodiques
Transfert de masse -- Périodiques
Electronic journals
621.4022 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00179310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijheatmasstransfer.2018.10.108 ↗
- Languages:
- English
- ISSNs:
- 0017-9310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.280000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9136.xml