A control for the day‐to‐day normalization of the flow cytometry γ‐H2AX assay for clinical routine. Issue 6 (27th February 2018)
- Record Type:
- Journal Article
- Title:
- A control for the day‐to‐day normalization of the flow cytometry γ‐H2AX assay for clinical routine. Issue 6 (27th February 2018)
- Main Title:
- A control for the day‐to‐day normalization of the flow cytometry γ‐H2AX assay for clinical routine
- Authors:
- Viktorisson, Adam
Mathew, Sherin T.
Hammarsten, Ola
Johansson, Pegah - Abstract:
- Abstract : Background: The phosphorylation of histone H2AX (γ‐H2AX) at the DNA double‐strand break (DSB) site is frequently used for quantifying DSBs and may be useful as a biomarker for clinical applications. We have previously reported a flow cytometry‐based quantification of γ‐H2AX for clinical routine. One major challenge, however, is the lack of a control sample for normalization of the day‐to‐day variation of the flow cytometry γ‐H2AX assay. Methods: Here, we report development of a mix‐control sample containing peripheral blood mononuclear cells (PBMC) from 10 control individuals, for normalization of day‐to‐day variation of the flow cytometry‐γ‐H2AX assay. Results: We showed that control individuals sampled on different days show an average day‐to‐day variation (CV) of 34%, which was reduced to 12% after normalization to the control sample. The normalization allowed detection of radiosensitivity of lymphoblastoid cell lines from ataxia telangiectasia patients, sampled over three days. Conclusion: The mix‐control sample, consisting of 10 control individuals' PBMC, can be used as a control sample to normalize for day‐to‐day variation of the γ‐H2AX assay. The use of this sample will facilitate integration of the γ‐H2AX assay into clinical routine. © 2018 International Clinical Cytometry Society
- Is Part Of:
- Cytometry. Volume 94:Issue 6(2018)
- Journal:
- Cytometry
- Issue:
- Volume 94:Issue 6(2018)
- Issue Display:
- Volume 94, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 94
- Issue:
- 6
- Issue Sort Value:
- 2018-0094-0006-0000
- Page Start:
- 946
- Page End:
- 949
- Publication Date:
- 2018-02-27
- Subjects:
- gamma‐H2AX -- DNA double‐strand breaks (DSBs) -- flow cytometry -- ionizing radiation (IR) -- day‐to‐day control
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21627 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9129.xml