Sensitivity of the IQM transmission detector to errors of VMAT plans. Issue 12 (25th October 2018)
- Record Type:
- Journal Article
- Title:
- Sensitivity of the IQM transmission detector to errors of VMAT plans. Issue 12 (25th October 2018)
- Main Title:
- Sensitivity of the IQM transmission detector to errors of VMAT plans
- Authors:
- Razinskas, Gary
Wegener, Sonja
Greber, Johannes
Sauer, Otto A. - Abstract:
- Abstract : Purpose: The integral quality monitor (IQM) transmission detector is a wedge‐shaped large area ionization chamber that reports a position‐weighted dose area product for each control point of an IMRT or VMAT plan. In this study, the accuracy of the signal prediction is verified for the Synergy Agility MLC. Tolerance criteria for VMAT plan verification with the IQM were obtained from the observed sensitivity for the detection of incorrectly delivered plans. Methods: The predicted IQM signal was compared to the measured signal recorded for a set of 30 VMAT plans for each beam quality of 6 and 10 MV. The system's capability to detect incorrectly delivered plans was tested by measuring altered plans containing small, random deviations. In addition, the observed deviations were related to measurements performed with a second QA phantom. Results: The cumulative IQM signal per arc deviated from the respective calculation on average by −0.48% (6 MV) and +0.21% (10 MV) with a standard deviation of 1.08% in both cases, suggesting a 2% warning and 3% action threshold as plan acceptance criteria. This choice was confirmed by the optimum threshold of 2.5% obtained via receiver operating characteristic (ROC) analysis. Reproducibility of individual control points in multiply measured plans was low (on average 7% for 1SD) and thus, segment‐by‐segment comparison was impractical. A suitable criterion to resolve the angular distribution of the plan was identified by binning three toAbstract : Purpose: The integral quality monitor (IQM) transmission detector is a wedge‐shaped large area ionization chamber that reports a position‐weighted dose area product for each control point of an IMRT or VMAT plan. In this study, the accuracy of the signal prediction is verified for the Synergy Agility MLC. Tolerance criteria for VMAT plan verification with the IQM were obtained from the observed sensitivity for the detection of incorrectly delivered plans. Methods: The predicted IQM signal was compared to the measured signal recorded for a set of 30 VMAT plans for each beam quality of 6 and 10 MV. The system's capability to detect incorrectly delivered plans was tested by measuring altered plans containing small, random deviations. In addition, the observed deviations were related to measurements performed with a second QA phantom. Results: The cumulative IQM signal per arc deviated from the respective calculation on average by −0.48% (6 MV) and +0.21% (10 MV) with a standard deviation of 1.08% in both cases, suggesting a 2% warning and 3% action threshold as plan acceptance criteria. This choice was confirmed by the optimum threshold of 2.5% obtained via receiver operating characteristic (ROC) analysis. Reproducibility of individual control points in multiply measured plans was low (on average 7% for 1SD) and thus, segment‐by‐segment comparison was impractical. A suitable criterion to resolve the angular distribution of the plan was identified by binning three to five control points as a running average. While the correlation between IQM signal deviations and gamma passing rates obtained with the ArcCHECK phantom was low for clinical plans, it was apparent for erroneous plans. Binning led to even higher sensitivity to errors. Conclusions: The IQM was able to detect induced errors at least as reliable as the standard phantom and showed the potential to be used in pretreatment plan verification to ensure the correct plan transfer and delivery. However, there is no direct correlation between the IQM signal deviation and DVH metrics, so the IQM should be primarily used to screen for errors. Finer diagnostics should then be carried out using a different phantom. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 12(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 12(2018)
- Issue Display:
- Volume 45, Issue 12 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 12
- Issue Sort Value:
- 2018-0045-0012-0000
- Page Start:
- 5622
- Page End:
- 5630
- Publication Date:
- 2018-10-25
- Subjects:
- IQM -- online dose monitoring -- quality assurance -- transmission detector
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13228 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9133.xml