Quantification of the seismic performance factors for steel diagrid structures. (July 2018)
- Record Type:
- Journal Article
- Title:
- Quantification of the seismic performance factors for steel diagrid structures. (July 2018)
- Main Title:
- Quantification of the seismic performance factors for steel diagrid structures
- Authors:
- Sadeghi, Saman
Rofooei, Fayaz R. - Abstract:
- Abstract: There are a number of studies on seismic performance of a diagrid structure indicating that it is an effective choice for constructing tall buildings. This research investigates the seismic behavior of diagrid structures and quantifies its seismic performance factors including the response modification coefficient (R-factor), the over-strength factor ( Ω 0 ) and the displacement amplification factor (Cd ) based on the FEMA P695 methodology. In that regard, a group of 3-D steel diagrid archetype models with different number of floors and various diagonal angles are designed using different R-factors. Then, in the first step, the over-strength factors of these models are determined by performing nonlinear static analyses. Then, utilizing the incremental dynamic analysis (IDA), the median collapse capacity and collapse margin ratio (CMR) of these models are calculated and their Cd factors are estimated using the computed R-factors. The obtained results indicate that the R-factor for steel diagrid systems depend on the diagonal angles. For diagrids with angles of 45°, 63.4° and 71.5°, amounts of R-factor were determined as 1.5, 2, and 3, respectively. Moreover, the pin and rigid types of end-connection of diagrid perimeter beams was found to have no effects on stiffness of the diagrid models. However, the IDA results indicate that the diagrids with pin-ended beams tolerate larger collapse displacements especially in shorter models. Furthermore, replacing theAbstract: There are a number of studies on seismic performance of a diagrid structure indicating that it is an effective choice for constructing tall buildings. This research investigates the seismic behavior of diagrid structures and quantifies its seismic performance factors including the response modification coefficient (R-factor), the over-strength factor ( Ω 0 ) and the displacement amplification factor (Cd ) based on the FEMA P695 methodology. In that regard, a group of 3-D steel diagrid archetype models with different number of floors and various diagonal angles are designed using different R-factors. Then, in the first step, the over-strength factors of these models are determined by performing nonlinear static analyses. Then, utilizing the incremental dynamic analysis (IDA), the median collapse capacity and collapse margin ratio (CMR) of these models are calculated and their Cd factors are estimated using the computed R-factors. The obtained results indicate that the R-factor for steel diagrid systems depend on the diagonal angles. For diagrids with angles of 45°, 63.4° and 71.5°, amounts of R-factor were determined as 1.5, 2, and 3, respectively. Moreover, the pin and rigid types of end-connection of diagrid perimeter beams was found to have no effects on stiffness of the diagrid models. However, the IDA results indicate that the diagrids with pin-ended beams tolerate larger collapse displacements especially in shorter models. Furthermore, replacing the rigid-ended beams by pin-ended beams improves the seismic performance of diagrids, particularly for models with larger diagonal angles (63.4° and 71.5°). The OpenSees program was used for modeling and numerical analyses. Highlights: The seismic performance factors of the steel diagrid structures with various diagonal angles are evaluated. Diagrid structures represent a brittle behavior with low ductility ratio and response modification factor (R). The seismic performance of diagrids depends on the diagonal angles. Increasing the diagonal angles of diagrids increases their ductility ratio and the R factors. The seismic performance of diagrids with pin-end and rigid end horizontal beams are compared. … (more)
- Is Part Of:
- Journal of constructional steel research. Volume 146(2018)
- Journal:
- Journal of constructional steel research
- Issue:
- Volume 146(2018)
- Issue Display:
- Volume 146, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 146
- Issue:
- 2018
- Issue Sort Value:
- 2018-0146-2018-0000
- Page Start:
- 155
- Page End:
- 168
- Publication Date:
- 2018-07
- Subjects:
- Diagrid steel structures -- FEMA P695 -- Seismic performance factors -- Incremental dynamic analysis -- Nonlinear static analysis
Steel, Structural -- Periodicals
Building, Iron and steel -- Periodicals
Acier de construction -- Périodiques
Construction métallique -- Périodiques
624.1821 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0143974X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcsr.2018.03.018 ↗
- Languages:
- English
- ISSNs:
- 0143-974X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.193000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9092.xml