Shah, Manjool - Abstract:
- Abstract : Purpose: To report a case of spontaneous dislocation of a gelatin microstent 6 months after the initial uncomplicated surgery. Patients and Methods: We describe a 73-year-old man with a history of advanced primary open-angle glaucoma who had previously undergone an unsuccessful micropulse transcleral cyclophotocoagulation of the left eye. He underwent an uncomplicated combined phacoemulsification with an ab interno gelatin microstent, but was noted to have a spontaneous dislocation of the microstent 6 months postoperatively. Results: His postoperative course was largely unremarkable. He underwent a total of 5 bleb needlings, 1 immediately postoperatively because of intra-Tenon's positioning of the microstent. At his 6-month follow-up, he had a needling with both 5-flurouracil and subconjunctival bevacizumab. Despite postprocedural gonioscopy confirmation of the microstent positioning, the patient returned 1 week later with a fully dislocated microstent. The dislocation was asymptomatic, and his intraocular pressure remained in the single digits. Conclusions: The ab interno gelatin microstent is a promising new procedure, but presents unique challenges. As the procedure is still new, more complications are expected to come to light. Although gelatin microstent migration and dislocation appears to be rare, it is important to recognize this postoperative complication. To our knowledge, this is the first report of a spontaneous dislocation of the gelatin microstentAbstract : Purpose: To report a case of spontaneous dislocation of a gelatin microstent 6 months after the initial uncomplicated surgery. Patients and Methods: We describe a 73-year-old man with a history of advanced primary open-angle glaucoma who had previously undergone an unsuccessful micropulse transcleral cyclophotocoagulation of the left eye. He underwent an uncomplicated combined phacoemulsification with an ab interno gelatin microstent, but was noted to have a spontaneous dislocation of the microstent 6 months postoperatively. Results: His postoperative course was largely unremarkable. He underwent a total of 5 bleb needlings, 1 immediately postoperatively because of intra-Tenon's positioning of the microstent. At his 6-month follow-up, he had a needling with both 5-flurouracil and subconjunctival bevacizumab. Despite postprocedural gonioscopy confirmation of the microstent positioning, the patient returned 1 week later with a fully dislocated microstent. The dislocation was asymptomatic, and his intraocular pressure remained in the single digits. Conclusions: The ab interno gelatin microstent is a promising new procedure, but presents unique challenges. As the procedure is still new, more complications are expected to come to light. Although gelatin microstent migration and dislocation appears to be rare, it is important to recognize this postoperative complication. To our knowledge, this is the first report of a spontaneous dislocation of the gelatin microstent without a clear inciting event. This case reiterates the importance of continued follow-up of these cases, and will hopefully help begin to shed light on preoperative considerations and patient selection. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 27:Issue 4(2018)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 27:Issue 4(2018)
- Issue Display:
- Volume 27, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2018-0027-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-04
- Subjects:
- XEN -- gelatin -- microstent -- dislocation -- micropulse
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000897 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9098.xml