An Innovative Solution for Prolonged Air Leaks: The Customized Endobronchial Silicone Blocker. Issue 2 (April 2018)
- Record Type:
- Journal Article
- Title:
- An Innovative Solution for Prolonged Air Leaks: The Customized Endobronchial Silicone Blocker. Issue 2 (April 2018)
- Main Title:
- An Innovative Solution for Prolonged Air Leaks
- Authors:
- Mehta, Ravindra M.
Singla, Abhinav
Bhat, Rajani S.
Godara, Rakesh
Lokanath, Chakravarthi
Cutaia, Michael - Abstract:
- Abstract : Background: Prolonged air leak (PAL) is a life-threatening condition that can present either as bronchopleural fistula, or alveolar-pleural fistula (APF). Although numerous bronchoscopic treatments are described, they are either expensive, not widely available in the developing world or have limited success. We describe our experience with a novel customized endobronchial silicone blocker (CESB) for PAL treatment. Methods: This is a retrospective study of PAL patients who underwent CESB placement. The air leak was localized using a balloon occlusion test. The CESB was uniquely designed by molding silicone stent pieces into a conical shape, deployed with rigid bronchoscopy into the appropriate segment, and reinforced with cyanoacrylate glue to prevent migration. In patients with APF, pleurodesis was performed after leak resolution to prevent recurrence. Following this, the CESB was removed after 6 weeks. Results: Forty-nine CESBs were placed in 31 patients (25 male individuals, 6 female individuals) with mean age of 49.7±19.7 years. The PALs included APF (n=16), bronchopleural fistula (n=14), and airway-mediastinal fistula (n=1). The average diameter of the CESB used was 7.9±2.9 mm. There was resolution of the PAL in 26 of 31 patients (84%). The CESB migrated in 5 patients with no adverse events. Pleurodesis was performed in 13 of 16 patients with APF, to prevent recurrence. No other significant complications were observed. Conclusions: CESBs represent a safe,Abstract : Background: Prolonged air leak (PAL) is a life-threatening condition that can present either as bronchopleural fistula, or alveolar-pleural fistula (APF). Although numerous bronchoscopic treatments are described, they are either expensive, not widely available in the developing world or have limited success. We describe our experience with a novel customized endobronchial silicone blocker (CESB) for PAL treatment. Methods: This is a retrospective study of PAL patients who underwent CESB placement. The air leak was localized using a balloon occlusion test. The CESB was uniquely designed by molding silicone stent pieces into a conical shape, deployed with rigid bronchoscopy into the appropriate segment, and reinforced with cyanoacrylate glue to prevent migration. In patients with APF, pleurodesis was performed after leak resolution to prevent recurrence. Following this, the CESB was removed after 6 weeks. Results: Forty-nine CESBs were placed in 31 patients (25 male individuals, 6 female individuals) with mean age of 49.7±19.7 years. The PALs included APF (n=16), bronchopleural fistula (n=14), and airway-mediastinal fistula (n=1). The average diameter of the CESB used was 7.9±2.9 mm. There was resolution of the PAL in 26 of 31 patients (84%). The CESB migrated in 5 patients with no adverse events. Pleurodesis was performed in 13 of 16 patients with APF, to prevent recurrence. No other significant complications were observed. Conclusions: CESBs represent a safe, effective, and innovative approach in the management of PAL. They should be considered in patients who are not surgical candidates, fail surgery, or those who have a recurrence following surgery. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of bronchology & interventional pulmonology. Volume 25:Issue 2(2018)
- Journal:
- Journal of bronchology & interventional pulmonology
- Issue:
- Volume 25:Issue 2(2018)
- Issue Display:
- Volume 25, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 2
- Issue Sort Value:
- 2018-0025-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-04
- Subjects:
- prolonged air leak -- bronchopleural fistula -- bronchoscopy -- blocker -- spigot
Bronchoscopy -- Periodicals
Lungs -- Diseases -- Periodicals
Respiratory Tract Diseases -- Periodicals
Lung Diseases -- surgery -- Periodicals
Diagnostic Techniques, Respiratory System -- Periodicals
Bronchi
Bronchoscopy
Lungs -- Diseases
Periodicals
616.23 - Journal URLs:
- http://journals.lww.com/bronchology/pages/default.aspx ↗
http://www.bronchology.com ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=ovft&AN=01436970-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/LBR.0000000000000459 ↗
- Languages:
- English
- ISSNs:
- 1944-6586
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.553000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9097.xml