The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery. Issue 2 (April 2018)
- Record Type:
- Journal Article
- Title:
- The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery. Issue 2 (April 2018)
- Main Title:
- The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery
- Authors:
- Carracedo, G.
Canales, J.
Gonzalez, P.
Recchioni, A.
Carpena-Torres, C.
Carballo-Álvarez, J. - Abstract:
- Highlights: The soft contact lens thickness role in the visual function has never been studied. More soft contact lens thickness improves visual quality after intrastromal rings. The rigidity of the soft contact lenses do not influence the aberrations correction. Abstract: Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A centralHighlights: The soft contact lens thickness role in the visual function has never been studied. More soft contact lens thickness improves visual quality after intrastromal rings. The rigidity of the soft contact lenses do not influence the aberrations correction. Abstract: Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction. … (more)
- Is Part Of:
- Contact lens & anterior eye. Volume 41:Issue 2(2018)
- Journal:
- Contact lens & anterior eye
- Issue:
- Volume 41:Issue 2(2018)
- Issue Display:
- Volume 41, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2018-0041-0002-0000
- Page Start:
- 180
- Page End:
- 186
- Publication Date:
- 2018-04
- Subjects:
- Keratoconus -- Intracorneal rings -- Visual function -- Contact lenses
Anterior segment (Eye) -- Periodicals
Contact lenses -- Periodicals
Segment antérieur (Œil) -- Périodiques
Lentilles de contact -- Périodiques
617.752305 - Journal URLs:
- http://firstsearch.oclc.org/journal=1367-0484;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/13670484 ↗
http://www.contactlensjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13670484 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13670484 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clae.2017.09.020 ↗
- Languages:
- English
- ISSNs:
- 1367-0484
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3424.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9088.xml