Cytomorphology and flow cytometry of brain biopsy rinse fluid enables faster and multidisciplinary diagnosis of large B‐cell lymphoma of the central nervous system. Issue 1 (29th August 2016)
- Record Type:
- Journal Article
- Title:
- Cytomorphology and flow cytometry of brain biopsy rinse fluid enables faster and multidisciplinary diagnosis of large B‐cell lymphoma of the central nervous system. Issue 1 (29th August 2016)
- Main Title:
- Cytomorphology and flow cytometry of brain biopsy rinse fluid enables faster and multidisciplinary diagnosis of large B‐cell lymphoma of the central nervous system
- Authors:
- Debliquis, Agathe
Voirin, Jimmy
Harzallah, Inès
Maurer, Maxime
Lerintiu, Felix
Drénou, Bernard
Ahle, Guido - Abstract:
- Abstract : Background: Central nervous system lymphomas are aggressive tumors requiring a prompt diagnosis for successful treatment. Stereotactic biopsy remains the standard procedure, but the time needed for histopathology is usually over 2 days. We evaluated the contribution of cytomorphology and flow cytometry to histopathology of the brain biopsy in particular on the rinse fluid usually removed. Methods: Eighteen patients with suspected localized brain lymphoma underwent stereotactic brain biopsy. Brain biopsy tissue sample and/or brain biopsy rinse fluid were analyzed by cytomorphology combined with flow cytometry. Histopathology was used as a reference. Results: Histopathology characterized ten diffuse large B‐cell lymphomas and eight other diseases. Cytomorphology and flow cytometry showed lymphoma cells in nine out of the ten lymphomas. Three cytomorphology or flow cytometry negative results were reported for lymphomas in tissue samples due to low cellularity and biopsy sample conditioning. No lymphomatous cells were found by cytomorphology or flow cytometry in the eight other diseases. Rinse fluid results were consistent with histology in all cases studied (sensitivity and specificity, 100%). The median time to result was 4.5 days (range, 2–10 days) for histopathology, while 5 h (range, 3–20 h) were required for both cytomorphology and flow cytometry. Conclusions: Brain biopsy rinse fluid alleviates problems of tissue sample distribution compared to tissue sample.Abstract : Background: Central nervous system lymphomas are aggressive tumors requiring a prompt diagnosis for successful treatment. Stereotactic biopsy remains the standard procedure, but the time needed for histopathology is usually over 2 days. We evaluated the contribution of cytomorphology and flow cytometry to histopathology of the brain biopsy in particular on the rinse fluid usually removed. Methods: Eighteen patients with suspected localized brain lymphoma underwent stereotactic brain biopsy. Brain biopsy tissue sample and/or brain biopsy rinse fluid were analyzed by cytomorphology combined with flow cytometry. Histopathology was used as a reference. Results: Histopathology characterized ten diffuse large B‐cell lymphomas and eight other diseases. Cytomorphology and flow cytometry showed lymphoma cells in nine out of the ten lymphomas. Three cytomorphology or flow cytometry negative results were reported for lymphomas in tissue samples due to low cellularity and biopsy sample conditioning. No lymphomatous cells were found by cytomorphology or flow cytometry in the eight other diseases. Rinse fluid results were consistent with histology in all cases studied (sensitivity and specificity, 100%). The median time to result was 4.5 days (range, 2–10 days) for histopathology, while 5 h (range, 3–20 h) were required for both cytomorphology and flow cytometry. Conclusions: Brain biopsy rinse fluid alleviates problems of tissue sample distribution compared to tissue sample. Its analysis performs the diagnosis of B‐cell lymphoma in a few hours and, associated with histopathology, allows a multidisciplinary diagnosis. This study shows that cytomorphology combined with flow cytometry on brain biopsy rinse fluid is a new, fast, and useful strategy. © 2016 International Clinical Cytometry Society … (more)
- Is Part Of:
- Cytometry. Volume 94:Issue 1(2018)
- Journal:
- Cytometry
- Issue:
- Volume 94:Issue 1(2018)
- Issue Display:
- Volume 94, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 94
- Issue:
- 1
- Issue Sort Value:
- 2018-0094-0001-0000
- Page Start:
- 182
- Page End:
- 188
- Publication Date:
- 2016-08-29
- Subjects:
- central nervous system lymphoma -- stereotactic brain biopsy -- cytomorphology -- flow cytometry
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21403 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9069.xml