Peripheral airway dysfunction and relationship with symptoms in smokers with preserved spirometry. Issue 5 (15th November 2017)
- Record Type:
- Journal Article
- Title:
- Peripheral airway dysfunction and relationship with symptoms in smokers with preserved spirometry. Issue 5 (15th November 2017)
- Main Title:
- Peripheral airway dysfunction and relationship with symptoms in smokers with preserved spirometry
- Authors:
- Jetmalani, Kanika
Thamrin, Cindy
Farah, Claude S.
Bertolin, Amy
Chapman, David G.
Berend, Norbert
Salome, Cheryl M.
King, Gregory G. - Abstract:
- ABSTRACT: Background and objective: Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms. Methods: Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection‐dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS. Results: Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty‐one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty‐one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other. Conclusions: Respiratory symptoms and peripheral airway dysfunction are common in smokers with normalABSTRACT: Background and objective: Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms. Methods: Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection‐dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS. Results: Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty‐one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty‐one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other. Conclusions: Respiratory symptoms and peripheral airway dysfunction are common in smokers with normal spirometry. Symptoms of chronic bronchitis related to conductive airway abnormalities, while wheeze was related to spirometry and IOS. The clinical significance of abnormalities in peripheral airway function in smokers remains undetermined. Abstract : See related Editorial Multiple breath nitrogen washout (MBNW) or impulse oscillometry system (IOS) abnormalities were highly prevalent in smokers without COPD but highly discordant between individuals. Cough was related to peripheral conductive airway function, while wheeze was related to IOS and spirometry. In smokers with normal spirometry, MBNW and IOS abnormalities may have different underlying structural bases and prognostic significance. … (more)
- Is Part Of:
- Respirology. Volume 23:Issue 5(2018)
- Journal:
- Respirology
- Issue:
- Volume 23:Issue 5(2018)
- Issue Display:
- Volume 23, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2018-0023-0005-0000
- Page Start:
- 512
- Page End:
- 518
- Publication Date:
- 2017-11-15
- Subjects:
- chronic obstructive pulmonary disease -- impulse oscillometry system -- multiple breath nitrogen washout -- small airways -- smoking
Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
612.2 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=res ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/resp.13215 ↗
- Languages:
- English
- ISSNs:
- 1323-7799
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.666000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9079.xml