Accuracy of Image‐Fusion Stereolithographic Guides: Mapping CT Data with Three‐Dimensional Optical Surface Scanning. (17th March 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of Image‐Fusion Stereolithographic Guides: Mapping CT Data with Three‐Dimensional Optical Surface Scanning. (17th March 2015)
- Main Title:
- Accuracy of Image‐Fusion Stereolithographic Guides: Mapping CT Data with Three‐Dimensional Optical Surface Scanning
- Authors:
- Widmann, Gerlig
Berggren, Johannes Peter Michael
Fischer, Bastian
Pichler‐Dennhardt, Albina Rosa
Schullian, Peter
Bale, Reto
Puelacher, Wolfgang - Abstract:
- Abstract: Background: Computer‐assisted implant surgery usually requires a radiographic scan template as the basis for prosthetic‐driven implant planning and surgical guide fabrication. Purpose: The study aims to evaluate the accuracy of image‐fusion stereolithographic guides in which a computed tomography (CT) scan is mapped with three‐dimensional optical scans of cast and diagnostic wax‐up. Materials and Methods: Three‐dimensional error at the base and tip of the implants, angular deviation of the implant‐axis, and the inserting‐depth error of 120 implants with a length of 10 mm and a caliber of 4.1 mm in 15 polymer‐models were examined. A control CT was performed and fused with the planning data for accuracy evaluation. Results: The mean three‐dimensional error was 0.21 ± 0.10 mm (0.00–0.48 mm) at the implant base, 0.32 ± 0.17 mm (0.03–0.75 mm) at the implant tip, and the mean angular error was 0.85 ± 0.59° (0.00–2.50°). The mean depth error was 0.07 ± 0.07 mm (0.00–0.32 mm). Conclusions: Within the limitations of an in vitro study, the novel technique showed excellent accuracy. Errors from fabrication and scanning of a radiographic scan template can be avoided, and the workflow and costs of computer‐assisted implant surgery may be reduced.
- Is Part Of:
- Clinical implant dentistry and related research. Volume 17(2015:Oct.)Supplement 2
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 17(2015:Oct.)Supplement 2
- Issue Display:
- Volume 17, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 2
- Issue Sort Value:
- 2015-0017-0002-0000
- Page Start:
- e736
- Page End:
- e744
- Publication Date:
- 2015-03-17
- Subjects:
- computerized tomography -- stereo lithography -- surgical guides
Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/cid.12313 ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9065.xml