Can applied external fixators be sterilized for surgery? A prospective cohort study of orthopaedic trauma patients. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Can applied external fixators be sterilized for surgery? A prospective cohort study of orthopaedic trauma patients. Issue 12 (December 2016)
- Main Title:
- Can applied external fixators be sterilized for surgery? A prospective cohort study of orthopaedic trauma patients
- Authors:
- Hardeski, David
Gaski, Greg
Joshi, Manjari
Venezia, Richard
Nascone, Jason W.
Sciadini, Marcus F.
O'Toole, Robert V. - Abstract:
- Abstract: Background: Temporary external fixators are often used to stabilize fractures when definitive fracture surgery must be delayed. Sometimes, external fixators are left in place during repeat operations, including definitive internal fixation of tibial pilon and tibial plateau fractures. It is unknown how well current surgical preparation sterilizes these devices, which become part of the surgical field. Our hypothesis was that our institution's standard surgical preparation creates a low rate of culture-positive environments on external fixators at the time of surgical skin incision. Methods: We prospectively consented and enrolled patients to obtain cultures (48 patients, 55 external fixators, 165 sets of culture data). After standard preparation and immediately before incision, cultures were obtained from three sites on each external fixator: 1) most distal pin 1 cm from pin-skin interface, 2) most distal bar at midpoint between pin and clamp connectors, and 3) most distal clamp at bar-clamp interface. Our standard preparation for patients with external fixation in place is to don sterile gloves and wipe down all components of the external fixator with 70% alcohol-soaked sterile 4 × 4 in gauze sponges before skin preparation. The skin and external fixator are then prepped in the usual fashion with ChloraPrep for closed wounds or with povidone iodine scrub and paint for open wounds. Swabs were processed and organisms from cultures identified. Clinicians were blindedAbstract: Background: Temporary external fixators are often used to stabilize fractures when definitive fracture surgery must be delayed. Sometimes, external fixators are left in place during repeat operations, including definitive internal fixation of tibial pilon and tibial plateau fractures. It is unknown how well current surgical preparation sterilizes these devices, which become part of the surgical field. Our hypothesis was that our institution's standard surgical preparation creates a low rate of culture-positive environments on external fixators at the time of surgical skin incision. Methods: We prospectively consented and enrolled patients to obtain cultures (48 patients, 55 external fixators, 165 sets of culture data). After standard preparation and immediately before incision, cultures were obtained from three sites on each external fixator: 1) most distal pin 1 cm from pin-skin interface, 2) most distal bar at midpoint between pin and clamp connectors, and 3) most distal clamp at bar-clamp interface. Our standard preparation for patients with external fixation in place is to don sterile gloves and wipe down all components of the external fixator with 70% alcohol-soaked sterile 4 × 4 in gauze sponges before skin preparation. The skin and external fixator are then prepped in the usual fashion with ChloraPrep for closed wounds or with povidone iodine scrub and paint for open wounds. Swabs were processed and organisms from cultures identified. Clinicians were blinded to study results until study completion. Results: Two of 165 cultures (1.2%; 95% confidence interval [CI]: 0–2.9%) were positive for common pathogens sometimes observed in surgical site infection. Four cultures (2.4%; 95% CI: 0–4.8%) had pathogens that are rarely associated with surgical site infection, and four (2.4%; 95% CI: 0–4.8%) had nonpathogenic organisms. Conclusion: Using 70% alcohol on external fixators plus either ChloraPrep for closed wounds or povidone iodine for open wounds seems to result in a low rate of positive cultures. Most species that were isolated are infrequently identified as sources of surgical site infections. This preparation protocol might be effective at producing a relatively clean environment at the time of surgery for patients with external fixators already in place. … (more)
- Is Part Of:
- Injury. Volume 47:Issue 12(2016)
- Journal:
- Injury
- Issue:
- Volume 47:Issue 12(2016)
- Issue Display:
- Volume 47, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 12
- Issue Sort Value:
- 2016-0047-0012-0000
- Page Start:
- 2679
- Page End:
- 2682
- Publication Date:
- 2016-12
- Subjects:
- External fixator -- Infection -- Sterilize -- Staphylococcus epidermis
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.07.009 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9055.xml