Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study. Issue 12 (December 2016)
- Main Title:
- Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study
- Authors:
- Dubois-Ferrière, Victor
Gamulin, Axel
Chowdhary, Ashwin
Fasel, Jean
Stern, Richard
Assal, Mathieu - Abstract:
- Abstract: Introduction: Syndesmotic disruption may be difficult to reduce and fix, and malreduction is associated with inferior outcomes. Intraoperative computed tomography (CT) can provide accurate assessment of syndesmotic reduction. We hypothesized that three-dimensional (3-D) computer-assisted orthopaedic surgery (CAOS) with navigation of syndesmotic reduction could avoid malreduction. Our goal was to assess feasibility and accuracy of such a technic in a cadaveric study. Method: Eleven through-the-knee cadaveric specimens were used. Ankle CT as control was obtained prior to intervention. The syndesmosis was destabilized by sectioning the tibiofibular ligaments, producing a malreduction temporarily fixed with a Kirschner wire (K-wire). With reference base fixed to the tibia an acquisition scan was made. A K-wire was fixed to the fibula. The K-wire holding the syndesmosis malreduced was removed. The fibula was reduced within the syndesmosis under 3-D CAOS using a navigated K-wire. Once optimal position was obtained by referencing control images, the syndesmosis was fixed with a 3.5 mm screw. A CT scan was performed to assess quality of reduction. Results: Position of the fibula in control and post-reduction CT scans showed a mean anterior-posterior displacement of 0.74 (±0.62)mm. The medial-lateral position measured a mean displacement of 0.68 (±0.76)mm. Rotation of the fibula revealed a mean difference of 0.99° (± 0.73). Conclusion: In this cadaveric study, CAOS withAbstract: Introduction: Syndesmotic disruption may be difficult to reduce and fix, and malreduction is associated with inferior outcomes. Intraoperative computed tomography (CT) can provide accurate assessment of syndesmotic reduction. We hypothesized that three-dimensional (3-D) computer-assisted orthopaedic surgery (CAOS) with navigation of syndesmotic reduction could avoid malreduction. Our goal was to assess feasibility and accuracy of such a technic in a cadaveric study. Method: Eleven through-the-knee cadaveric specimens were used. Ankle CT as control was obtained prior to intervention. The syndesmosis was destabilized by sectioning the tibiofibular ligaments, producing a malreduction temporarily fixed with a Kirschner wire (K-wire). With reference base fixed to the tibia an acquisition scan was made. A K-wire was fixed to the fibula. The K-wire holding the syndesmosis malreduced was removed. The fibula was reduced within the syndesmosis under 3-D CAOS using a navigated K-wire. Once optimal position was obtained by referencing control images, the syndesmosis was fixed with a 3.5 mm screw. A CT scan was performed to assess quality of reduction. Results: Position of the fibula in control and post-reduction CT scans showed a mean anterior-posterior displacement of 0.74 (±0.62)mm. The medial-lateral position measured a mean displacement of 0.68 (±0.76)mm. Rotation of the fibula revealed a mean difference of 0.99° (± 0.73). Conclusion: In this cadaveric study, CAOS with navigation allowed for very accurate syndesmosis reduction. This appears to be a promising technique to be confirmed by clinical study. … (more)
- Is Part Of:
- Injury. Volume 47:Issue 12(2016)
- Journal:
- Injury
- Issue:
- Volume 47:Issue 12(2016)
- Issue Display:
- Volume 47, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 12
- Issue Sort Value:
- 2016-0047-0012-0000
- Page Start:
- 2694
- Page End:
- 2699
- Publication Date:
- 2016-12
- Subjects:
- Syndesmosis -- Computer-assisted -- Reduction -- Navigation -- Cadaver
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.10.009 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9055.xml